Lennox Error Code LED1 OFF / LED2 SLOW flash: Prove switch (pressure switch) open (Furnace)

Updated · by Aurora Star Tech Inc.

Lennox error code LED1 OFF / LED2 SLOW flash on a furnace means: Prove switch (pressure switch) open. It is also called Lennox diagnostic code LED1 OFF / LED2 SLOW flash.

High severityFurnaceLennox G43UF

Homeowner? What Lennox code LED1 OFF / LED2 SLOW flash means for you

Call a technician Your furnace is reporting: Prove switch (pressure switch) open. The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Make sure the furnace front door or panel is closed properly; many furnaces will not run with the door switch open.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the gas valve next to the furnace is open (handle in line with the pipe). Do not force it.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Lennox error code LED1 OFF / LED2 SLOW flash mean?

The prove switch is not closing with the combustion air inducer running, or it is closed before the inducer starts. Covers blocked intake or exhaust vent too. Shows up as no heat, or burners lighting then shutting off early.

Applies to: G43UF-24B-045 through G43UF-60D-135 (SureLight boards 32M88, 78M47, 100973-01)

Common causes of Lennox code LED1 OFF / LED2 SLOW flash

  • Prove switch stuck closed before the inducer starts
  • Inducer wiring wrong or loose, or inducer failed
  • Prove switch tubing routed wrong, pinched, broken, blocked or holding condensate

A technician checks these and 4 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Lennox models that use code LED1 OFF / LED2 SLOW flash

G43UF-24B-045G43UF-24B-070G43UF-36B-070G43UF-36C-090G43UF-36C-090HG43UF-48C-090G43UF-48C-110G43UF-48C-110HG43UF-60C-110G43UF-60D-135

Other Lennox Furnace codes

CodeMeaning
LED1 & LED2 alternating SLOW flashWatchguard lockout - burners failed to ignite or repeated failures
LED1 & LED2 simultaneous FAST flashNormal - heat call in progress
LED1 & LED2 simultaneous SLOW flashNormal - power on, idle, cooling or continuous fan
LED1 FAST flash / LED2 SLOW flash120 V line and neutral reversed
LED1 OFF / LED2 OFFNo power to the control
LED1 OFF / LED2 ONControl board failure or control wired incorrectly
LED1 ON / LED2 OFFControl board failure or control wired incorrectly
LED1 ON / LED2 ONControl board failure or control wired incorrectly
LED1 ON / LED2 SLOW flashRollout switch open
LED1 SLOW flash / LED2 FAST flashLow flame signal
LED1 SLOW flash / LED2 OFFFlame sensed with gas valve not energized
LED1 SLOW flash / LED2 ONPrimary or secondary limit open

All Lennox Furnace error codes →

Lennox code LED1 OFF / LED2 SLOW flash: homeowner questions

What does Lennox code LED1 OFF / LED2 SLOW flash mean?

Prove switch (pressure switch) open. The prove switch is not closing with the combustion air inducer running, or it is closed before the inducer starts. Covers blocked intake or exhaust vent too. Shows up as no heat, or burners lighting then shutting off early.

Is it safe to keep using my furnace with code LED1 OFF / LED2 SLOW flash?

It depends on the cause. The furnace has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Lennox code LED1 OFF / LED2 SLOW flash myself?

You can try one reset (power off for 30 seconds, then on). If Lennox code LED1 OFF / LED2 SLOW flash comes back, the cause is still there and a licensed technician should check it.

Who can fix Lennox code LED1 OFF / LED2 SLOW flash near me?

Aurora Star Tech Inc. repairs Lennox furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: Lennox G43UF Unit Information Corp. 0416-L4, Troubleshooting Chart Problems 2.2, 2.3, 3.1, 5.1 pp.51-53 and Table 4 p.11. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977