Lennox Error Code E409: Outdoor control low 24 VAC (Heat Pump)

Updated · by Aurora Star Tech Inc.

Lennox error code E409 on a heat pump means: Outdoor control low 24 VAC. It is also called Lennox diagnostic code E409.

Medium severityHeat Pump

Homeowner? What Lennox code E409 means for you

Check, then call Your heat pump is reporting: Outdoor control low 24 VAC. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Lennox error code E409 mean?

Secondary voltage at the outdoor control fell below 18 VAC; after 10 minutes the thermostat turns that unit off. S30/S40 thermostat alert code 409 (shown as E409 on the unit control display).

Applies to: Lennox communicating heat pumps incl. variable-capacity inverter units in S30/S40 smart thermostat systems

Common causes of Lennox code E409

  • Overloaded or weak transformer
  • Long or undersized thermostat wire
  • Loose connection
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Lennox models that use code E409

EL16KP1-018EL16KP1-024EL16KP1-030EL16KP1-036EL16KP1-042EL16KP1-048EL16KP1-060ML14KP1-018ML14KP1-024ML14KP1-030ML14KP1-036ML14KP1-042ML14KP1-048ML14KP1-060

Other Lennox Heat Pump codes

CodeMeaning
E403Compressor short-cycling
E404Compressor rotor locked
E405Compressor open circuit
E406Compressor open start circuit
E407Compressor open run circuit
E408Compressor contactor welded
E410Open low pressure switch
E411Low pressure switch strikes lockout
E412Open high pressure switch
E413High pressure switch strikes lockout
E414High discharge line temperature
E415High discharge line temperature strikes lockout

All Lennox Heat Pump error codes →

Lennox code E409: homeowner questions

What does Lennox code E409 mean?

Outdoor control low 24 VAC. Secondary voltage at the outdoor control fell below 18 VAC; after 10 minutes the thermostat turns that unit off. S30/S40 thermostat alert code 409 (shown as E409 on the unit control display).

Is it safe to keep using my heat pump with code E409?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Lennox code E409 myself?

You can try one reset (power off for 30 seconds, then on). If Lennox code E409 comes back, the cause is still there and a licensed technician should check it.

Who can fix Lennox code E409 near me?

Aurora Star Tech Inc. repairs Lennox heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Lennox Residential Communicating Systems Alert Code Guide (V2) 100017 (3/2023), Table 2 Alert Codes and Troubleshooting, p.30. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977