Updated · by Aurora Star Tech Inc.

Lennox error code E201 on a air handler means: Blower motor communication fault. It is also called Lennox diagnostic code E201.

High severityAir Handler

Homeowner? What Lennox code E201 means for you

Call a technician Your air handler is reporting: Blower motor communication fault. The air handler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Lennox error code E201 mean?

Lost communication with the indoor blower motor. S30/S40 thermostat alert code 201 (shown as E201 on the unit control display).

Applies to: Lennox communicating air handlers and EIM-equipped indoor units in S30/S40 smart thermostat systems

Common causes of Lennox code E201

  • Power outage or brownout
  • Motor not powered
  • Loose wiring

A technician checks these and 2 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Lennox Air Handler codes

CodeMeaning
E124Thermostat lost communication to smart hub
E125Control hardware problem
E126Control internal communication problem
E130Configuration jumper missing
E132Device control software fault
E180Outdoor temperature sensor problem
E202Blower motor and unit size mismatch
E203Invalid unit size code
E292Blower motor start fault
E295Blower motor over temperature
E310Discharge air temperature sensor problem
E312Reduced airflow - indoor blower cutback

All Lennox Air Handler error codes →

Lennox code E201: homeowner questions

What does Lennox code E201 mean?

Blower motor communication fault. Lost communication with the indoor blower motor. S30/S40 thermostat alert code 201 (shown as E201 on the unit control display).

Is it safe to keep using my air handler with code E201?

It depends on the cause. The air handler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Lennox code E201 myself?

You can try one reset (power off for 30 seconds, then on). If Lennox code E201 comes back, the cause is still there and a licensed technician should check it.

Who can fix Lennox code E201 near me?

Aurora Star Tech Inc. repairs Lennox air handlers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Troubleshooting guides

Source: Lennox Residential Communicating Systems Alert Code Guide (V2) 100017 (3/2023), Table 2 Alert Codes and Troubleshooting, p.19. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.