Carrier Heat Pump error codes list

CodeMeaningSeverity
----Indoor units mode conflictMedium
1Normal operation - 1 flashLow
1 longCapacity limited - one long flashLow
2Normal operation - 2 flashes (high stage)Low
3Three flashes - outdoor fan delay after defrost active (24ANB/25HNB)Low
4Four flashes - speed limiting (25VNA8) / fan delay defeat on (24ANB/25HNB)Low
5Five flashes - brownout protection setting (24ANB/25HNB)Low
6Six flashes - brownout protection setting (24ANB/25HNB)Low
16Lost communication with user interfaceMedium
25Invalid model plug / inverter sizeHigh
31High pressure switch openHigh
32Low pressure tripMedium
33Lost inverter communicationMedium
45Outdoor control board failureHigh
46BrownoutMedium
47No 230 V at unitHigh
48Lost inverter communication - lockoutHigh
49Compressor over currentMedium
53Outdoor air temperature sensor faultMedium
54Suction temperature sensor faultMedium
55Outdoor coil temperature sensor faultMedium
56OAT / coil thermistor out of rangeMedium
57Suction pressure transducer faultMedium
59Discharge temperature high (event)Medium
61Fan inverter faultMedium
63Fan inverter current faultMedium
65DC bus voltage low - speed limitingMedium
66Outdoor fan dropped outMedium
67Stator heater faultMedium
6810-minute stage 2 warm-up delayLow
69Inverter / compressor internal faultHigh
71Compressor dropped outMedium
72Suction over temperature (event)Medium
73Contactor shortedHigh
74Discharge temperature lockoutHigh
75Maximum power mode - temperatureMedium
76Fan inverter lockoutHigh
77Maximum power mode - compressor currentMedium
79Compressor / inverter fault (failed start)Medium
81Low stage thermal lockoutHigh
82Suction over temperature lockoutHigh
83Low pressure lockout (4 hours)High
84High pressure lockout (4 hours)High
86Fan inverter current lockoutHigh
88Compressor / inverter lockoutHigh
91Inverter DC over voltage (event)Medium
92Inverter DC under voltage (event)Medium
95Compressor over current lockoutHigh
96DC under voltage lockoutHigh
97DC over voltage lockoutHigh
98High torque eventMedium
99High torque lockoutHigh
341 MCE error341 MCE errorMedium
Charging modeRefrigerant charging mode (25VNA8/24VNA9, communicating)Low
COMM LEDGreen COMM LED on - communicatingLow
CurtailmentUtility curtailment shown on user interfaceLow
DFDefrost modeLow
EC 0dOutdoor unit malfunctionMedium
EC0dODU malfunctionHigh
EC 07Outdoor fan speed operating outside normal rangeMedium
EC07ODU fan speed out of controlMedium
EC 5CQuick maintenance code (outdoor)Medium
EC 50Temperature sensor open or shortedMedium
EC 51EEPROM malfunction (outdoor unit)High
EC51ODU EEPROM parameter errorHigh
EC 52Outdoor temperature sensor open or shortMedium
EC52ODU coil temp sensor errorMedium
EC 53Outdoor temperature sensor open or shortMedium
EC53ODU ambient temp sensor errorMedium
EC 54Outdoor temperature sensor open or shortMedium
EC54COMP. discharge temp sensor errorMedium
EC 55Quick maintenance code (outdoor)Medium
EC 56Outdoor temperature sensor open or shortMedium
EC56IDU coil outlet temp sensor errorMedium
EC 57Quick maintenance code (outdoor)Medium
ECC1Other IDU refrigerant sensor detects leakage (multi-zone)High
EH 0AEEPROM malfunction (indoor unit)High
EH0AIDU EEPROM parameter errorHigh
EH 0bIndoor main control board and display board communication errorMedium
EH0bIDU main control and display boards communication errorMedium
EH0EWater-level alarm malfunctionMedium
EH 0EWater-level alarm malfunctionMedium
EH 00EEPROM malfunction (indoor unit)High
EH00IDU EEPROM malfunctionHigh
EH 03Indoor fan speed outside normal rangeMedium
EH03IDU fan speed out of controlMedium
EH 03 / EC 07Fan speed outside normal rangeMedium
EH 3AExternal fan DC bus voltage too low protectionMedium
EH3AExternal fan DC bus voltage too low protectionMedium
EH 3bExternal fan DC bus voltage too high faultMedium
EH3bExternal fan DC bus voltage too high faultMedium
EH 60Indoor temperature sensor open or shortMedium
EH60IDU room temp. sensor (T1) errorMedium
EH 61Indoor temperature sensor open or shortMedium
EH61IDU coil temp. sensor (T2) errorMedium
EH 62Indoor temperature sensor open or shortMedium
EH62/EH66Evaporator coil inlet temp. sensor (T2B) open or short circuitMedium
EH 65Indoor temperature sensor open or shortMedium
EH65Evaporator coil inlet temp. sensor (T2A) open or short circuitMedium
EH 66Indoor temperature sensor open or shortMedium
EH b3Communication malfunction between wired controller and master controlMedium
EHb3Communication malfunction between wire controller and master controlMedium
EH bACommunication malfunction between indoor unit and external fan moduleMedium
EHbACommunication error between indoor unit and external fan moduleMedium
EH C1Refrigerant sensor detects leakageHigh
EHC1Refrigerant sensor detects leakageCritical
EH C2Refrigerant sensor out of range and leakage detectedCritical
EHC2Refrigerant sensor out of range and leakage detectedCritical
EH C3Refrigerant sensor out of rangeMedium
EHC3Refrigerant sensor out of rangeHigh
EL 0CSystem lacks refrigerantMedium
EL0CSystem lacks refrigerantHigh
EL 01Indoor and outdoor unit communication errorMedium
EL01IDU & ODU communication errorMedium
EL 16Communication malfunction between adapter board and outdoor main boardMedium
EL16Communication malfunction between adapter board and outdoor main boardMedium
FCForced cooling modeLow
FH CCRefrigerant sensor errorMedium
FHCCRefrigerant sensor errorHigh
FL 09Mismatch between new and old platformsMedium
FL09Mismatch between the new and old platformsMedium
Forced defrostForced defrost (short the defrost pins)Low
LC 06Compressor top (IPM) temperature protectionHigh
LD1MOC red LED LD1 (sizes 25-60)Low
LD5MOC green LED LD5 (sizes 25-60)Low
LED1MOC red LED1 (sizes 25-60)Low
LED3MOC amber LED3 (sizes 25-60)Low
LED200MOC red LED (sizes 13, 24B)Low
LED207MOC amber LED (sizes 13, 24B)Low
ONAmber STATUS LED on solid - standbyLow
PC 0aQuick maintenance code (outdoor)High
PC 0FQuick maintenance code (outdoor)High
PC 0LLow ambient temperature protectionMedium
PC0LLow ambient temp. protectionLow
PC00ODU IPM module protectionHigh
PC 00Outdoor IPM module protectionCritical
PC01ODU voltage protectionHigh
PC 01Outdoor voltage protectionHigh
PC02Compressor top (or IPM) temp. protectionHigh
PC 02Compressor top or IPM temperature protectionHigh
PC03Pressure protection (low or high pressure)High
PC 03High or low pressure protectionHigh
PC04Inverter compressor drive errorHigh
PC 04Inverter compressor drive errorHigh
PC 06Quick maintenance code (outdoor)High
PC 08Quick maintenance code (outdoor)High
PC 10Quick maintenance code (outdoor)High
PC 11Quick maintenance code (outdoor)High
PC 12Quick maintenance code (outdoor)High
PC 30Quick maintenance code (outdoor)High
PC 31Quick maintenance code (outdoor)High
PC 40Quick maintenance code (outdoor)High
PC 41Quick maintenance code (outdoor)High
PC 42Quick maintenance code (outdoor)High
PC 43Quick maintenance code (outdoor)High
PC 44Quick maintenance code (outdoor)High
PC 45Quick maintenance code (outdoor)High
PC 46Quick maintenance code (outdoor)High
PC 49Quick maintenance code (outdoor)High
PH 90Quick maintenance code (outdoor)High
PH 91Quick maintenance code (outdoor)High
Status code recallStatus code recall mode (25VNA8/24VNA9)Low

Find codes by Carrier model

Carrier 2-stage 24ANB/25HNB

25HNB62425HNB63625HNB64825HNB66025HNB92425HNB93625HNB94825HNB960

Carrier Infinity 18VS 25VNA8

25VNA81325VNA82425VNA82525VNA83625VNA83725VNA84825VNA860

D5FCFA

37MAHAQ37MARAQ37MGHAQ37MGRAQ

D5FUAA

37MUHA37MURAD5FUAAH18AAKD5FUAAH24AAKD5FUAAH30AAKD5FUAAH36AAKD5FUAAH48AAKD5FUAAH60AAK

D5CURA

D5CURA + D5MUWAD5CURAH18AAKD5CURAH24AAKD5CURAH30AAKD5CURAH36AAKD5CURAH48AAKD5CURAH60AAK

Heat Pump troubleshooting guides

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.