Carrier Heat Pump: Buried refrigerant piping limits

Updated · by Aurora Star Tech Inc.

Buried refrigerant piping limits on a Carrier heat pump: Do not bury more than 36 in (914 mm) of refrigerant pipe. Any buried section needs a 6 in (152 mm) vertical rise to the outdoor valve connections, or refrigerant can migrate and cause slugging at start-up.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Field refrigerant piping

How to fix buried refrigerant piping limits: step by step

  1. Limit buried pipe to 36 in (914 mm).
  2. Provide a 6 in (152 mm) vertical rise to the outdoor valve connections.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Carrier Heat Pump codes

Models

D5CURA + D5MUWAD5CURAH18AAKD5CURAH24AAKD5CURAH30AAKD5CURAH36AAKD5CURAH48AAKD5CURAH60AAK

More other tips for heat pump

Source: D5CURA installation manual, p. 2. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.