Carrier Heat Pump: 24K/36K/48K electrical parts and main control board removal
24K/36K/48K electrical parts and main control board removal on a Carrier heat pump: Procedure to remove the electronic control box subassembly and the main control board. Anti-static gloves must be worn for this work.
Applies to: 24K, 36K and 48K indoor units
How to fix 24k/36k/48k electrical parts and main control board removal: step by step
- Wear anti-static gloves.
- Remove the 3 screws of the electronic control box and the 1 screw of the earth wire.
- Disconnect the connectors of the temperature sensor, pump, motor and water level switch.
- Remove the electronic control box subassembly.
- Remove the 2 screws of the main control board and the 2 screws of the earth wire.
- Disconnect the connectors, then remove the main control board.
If the unit shows an error code, look it up: Carrier Heat Pump codes
Source: D5FSCAH / D5FLCAH service manual, p. 69. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.