Carrier Heat Pump: Limit buried refrigerant pipe length

Updated · by Aurora Star Tech Inc.

Limit buried refrigerant pipe length on a Carrier heat pump: Buried refrigerant line is limited so refrigerant does not migrate to the cold buried section and slug the compressor at start-up.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Refrigerant line installation

How to fix limit buried refrigerant pipe length: step by step

  1. Do not bury more than 36 in. (914 mm) of refrigerant pipe.
  2. If any section is buried, provide a 6 in. (152 mm) vertical rise to the outdoor unit valve connections.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Carrier Heat Pump codes

Models

37MUHA37MURAD5FUAAH18AAKD5FUAAH24AAKD5FUAAH30AAKD5FUAAH36AAKD5FUAAH48AAKD5FUAAH60AAK

More commissioning tips for heat pump

Source: D5FUAA Service Manual, p. 1. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.