Carrier Error Code EH bA: Communication malfunction between indoor unit and external fan module (Heat Pump)

Updated · by Aurora Star Tech Inc.

Carrier error code EH bA on a heat pump means: Communication malfunction between indoor unit and external fan module. It is also called Carrier diagnostic code EH bA.

Medium severityHeat PumpD5FUAA

Homeowner? What Carrier code EH bA means for you

Check, then call Your heat pump is reporting: Communication malfunction between indoor unit and external fan module. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Carrier error code EH bA mean?

The indoor unit does not receive feedback from the external fan module for 150 seconds, or it receives abnormal voltage changes from the module.

Applies to: D5FUAA indoor unit with external fan module

Common causes of Carrier code EH bA

  • Communication loss to the external fan module
  • Abnormal voltage from the external fan module
  • Faulty indoor main PCB
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Carrier models that use code EH bA

37MUHA37MURAD5FUAAH18AAKD5FUAAH24AAKD5FUAAH30AAKD5FUAAH36AAKD5FUAAH48AAKD5FUAAH60AAK

Other Carrier Heat Pump codes

CodeMeaning
EH62/EH66Evaporator coil inlet temp. sensor (T2B) open or short circuit
EH 65Indoor temperature sensor open or short
EH65Evaporator coil inlet temp. sensor (T2A) open or short circuit
EH 66Indoor temperature sensor open or short
EH b3Communication malfunction between wired controller and master control
EHb3Communication malfunction between wire controller and master control
EHbACommunication error between indoor unit and external fan module
EH C1Refrigerant sensor detects leakage
EHC1Refrigerant sensor detects leakage
EH C2Refrigerant sensor out of range and leakage detected
EHC2Refrigerant sensor out of range and leakage detected
EH C3Refrigerant sensor out of range

All Carrier Heat Pump error codes →

Carrier code EH bA: homeowner questions

What does Carrier code EH bA mean?

Communication malfunction between indoor unit and external fan module. The indoor unit does not receive feedback from the external fan module for 150 seconds, or it receives abnormal voltage changes from the module.

Is it safe to keep using my heat pump with code EH bA?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Carrier code EH bA myself?

You can try one reset (power off for 30 seconds, then on). If Carrier code EH bA comes back, the cause is still there and a licensed technician should check it.

Who can fix Carrier code EH bA near me?

Aurora Star Tech Inc. repairs Carrier heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: D5FUAA service manual, p. 37. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.