Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Carrier Error Code LED207: MOC amber LED (sizes 13, 24B) (Heat Pump)

Updated · by Aurora Star Tech Inc.

Carrier error code LED207 on a heat pump means: MOC amber LED (sizes 13, 24B). It is also called Carrier diagnostic code LED207.

Low severityHeat PumpCarrier Infinity 18VS 25VNA8

Homeowner? What Carrier code LED207 means for you

Usually minor Your heat pump is reporting: MOC amber LED (sizes 13, 24B). This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Carrier error code LED207 mean?

Amber LED on the inverter (MOC) board, sizes 13 and 24B. Steady on means the compressor is running. Off means the compressor is stopped with no fault. Blinking while the compressor is stopped points to a fault, and blinking while it is running means compressor speed is limited or reduced.

Applies to: Carrier Infinity 25VNA8/24VNA9 inverter board (sizes 13 and 24B)

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Carrier models that use code LED207

25VNA81325VNA82425VNA82525VNA83625VNA83725VNA84825VNA860

Other Carrier Heat Pump codes

CodeMeaning
LC 06Compressor top (IPM) temperature protection
LD1MOC red LED LD1 (sizes 25-60)
LD5MOC green LED LD5 (sizes 25-60)
LED1MOC red LED1 (sizes 25-60)
LED3MOC amber LED3 (sizes 25-60)
LED200MOC red LED (sizes 13, 24B)
ONAmber STATUS LED on solid - standby
PC 0aQuick maintenance code (outdoor)
PC 0FQuick maintenance code (outdoor)
PC 0LLow ambient temperature protection
PC0LLow ambient temp. protection
PC00ODU IPM module protection

All Carrier Heat Pump error codes →

Carrier code LED207: homeowner questions

What does Carrier code LED207 mean?

MOC amber LED (sizes 13, 24B). Amber LED on the inverter (MOC) board, sizes 13 and 24B. Steady on means the compressor is running. Off means the compressor is stopped with no fault. Blinking while the compressor is stopped points to a fault, and blinking while it is…

Is it safe to keep using my heat pump with code LED207?

Usually yes. Code LED207 is normally minor, but if it keeps coming back have it checked.

Can I reset Carrier code LED207 myself?

You can try one reset (power off for 30 seconds, then on). If Carrier code LED207 comes back, the cause is still there and a licensed technician should check it.

Who can fix Carrier code LED207 near me?

Aurora Star Tech Inc. repairs Carrier heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Carrier 25VNA8/24VNA9 service manual, Variable Speed Drive LED Location and Description, p.26-27. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service