Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Carrier Error Code 32: Low pressure trip (Heat Pump)

Updated · by Aurora Star Tech Inc.

Carrier error code 32 on a heat pump means: Low pressure trip. It is also called Carrier diagnostic code 32.

Medium severityHeat PumpCarrier Infinity 18VS 25VNA8 · Carrier 2-stage 24ANB/25HNB · Carrier single-stage communicating HP

Homeowner? What Carrier code 32 means for you

Check, then call Your heat pump is reporting: Low pressure trip. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Carrier error code 32 mean?

Amber STATUS light flashes 32. Suction pressure dropped below the trip point (cooling about 33 psig or less, heating about 15 psig or less). After 3 trips it becomes code 83 (4-hour lockout). Type: Local; reset: 6 minutes.

Applies to: Carrier Infinity 18VS variable speed heat pump 25VNA8 (AOC control + inverter)

Common causes of Carrier code 32

  • See code 83 for causes
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Carrier models that use code 32

25HNB62425HNB63625HNB64825HNB66025HNB92425HNB93625HNB94825HNB96025VNA81325VNA82425VNA82525VNA83625VNA83725VNA84825VNA860

Other Carrier Heat Pump codes

CodeMeaning
4Four flashes - speed limiting (25VNA8) / fan delay defeat on (24ANB/25HNB)
5Five flashes - brownout protection setting (24ANB/25HNB)
6Six flashes - brownout protection setting (24ANB/25HNB)
16Lost communication with user interface
25Invalid model plug / inverter size
31High pressure switch open
33Lost inverter communication
45Outdoor control board failure
46Brownout
47No 230 V at unit
48Lost inverter communication - lockout
49Compressor over current

All Carrier Heat Pump error codes →

Carrier code 32: homeowner questions

What does Carrier code 32 mean?

Low pressure trip. Amber STATUS light flashes 32. Suction pressure dropped below the trip point (cooling about 33 psig or less, heating about 15 psig or less). After 3 trips it becomes code 83 (4-hour lockout). Type: Local; reset: 6 minutes.

Is it safe to keep using my heat pump with code 32?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Carrier code 32 myself?

You can try one reset (power off for 30 seconds, then on). If Carrier code 32 comes back, the cause is still there and a licensed technician should check it.

Who can fix Carrier code 32 near me?

Aurora Star Tech Inc. repairs Carrier heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Carrier 25VNA8 / 24VNA9 Service Manual, Table 6 Fault Code Actions, p.19. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service