Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Carrier Error Code Charging mode: Refrigerant charging mode (25VNA8/24VNA9, communicating) (Heat Pump)

Updated · by Aurora Star Tech Inc.

Carrier error code Charging mode on a heat pump means: Refrigerant charging mode (25VNA8/24VNA9, communicating). It is also called Carrier diagnostic code Charging mode.

Low severityHeat PumpCarrier Infinity 18VS 25VNA8

Homeowner? What Carrier code Charging mode means for you

Usually minor Your heat pump is reporting: Refrigerant charging mode (25VNA8/24VNA9, communicating). This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Carrier error code Charging mode mean?

Mode on the Infinity user interface, opened from the Installation and Service screen, used to check or set refrigerant charge. The screen offers weigh-in or heating check charge methods; the heating check runs the system at stage 5 with matched outdoor fan and indoor airflow and counts down while it stabilizes. A service-valve subcooling option appears only when outdoor and indoor temperatures are in range, otherwise it is greyed out.

Applies to: Carrier Infinity 25VNA8/24VNA9 communicating systems

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Carrier models that use code Charging mode

25VNA81325VNA82425VNA82525VNA83625VNA83725VNA84825VNA860

Other Carrier Heat Pump codes

CodeMeaning
95Compressor over current lockout
96DC under voltage lockout
97DC over voltage lockout
98High torque event
99High torque lockout
341 MCE error341 MCE error
COMM LEDGreen COMM LED on - communicating
CurtailmentUtility curtailment shown on user interface
DFDefrost mode
EC 0dOutdoor unit malfunction
EC0dODU malfunction
EC 07Outdoor fan speed operating outside normal range

All Carrier Heat Pump error codes →

Carrier code Charging mode: homeowner questions

What does Carrier code Charging mode mean?

Refrigerant charging mode (25VNA8/24VNA9, communicating). Mode on the Infinity user interface, opened from the Installation and Service screen, used to check or set refrigerant charge. The screen offers weigh-in or heating check charge methods; the heating check runs the system at stage 5 with…

Is it safe to keep using my heat pump with code Charging mode?

Usually yes. Code Charging mode is normally minor, but if it keeps coming back have it checked.

Can I reset Carrier code Charging mode myself?

You can try one reset (power off for 30 seconds, then on). If Carrier code Charging mode comes back, the cause is still there and a licensed technician should check it.

Who can fix Carrier code Charging mode near me?

Aurora Star Tech Inc. repairs Carrier heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Carrier 25VNA8/24VNA9 service manual, Check Charge and Heating Check Chart Procedure, p.9-12. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977