Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Carrier Error Code FH CC: Refrigerant sensor error (Heat Pump)

Updated · by Aurora Star Tech Inc.

Carrier error code FH CC on a heat pump means: Refrigerant sensor error. It is also called Carrier diagnostic code FH CC.

Medium severityHeat PumpD5FUAA

Homeowner? What Carrier code FH CC means for you

Check, then call Your heat pump is reporting: Refrigerant sensor error. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Carrier error code FH CC mean?

The indoor unit receives a fault signal from the refrigerant sensor for 10 s, or it gets no feedback from the sensor for 150 s. The manual prints this code as FH CC; it may be a typo for EH CC.

Applies to: D5FUAA indoor unit with refrigerant sensor

Common causes of Carrier code FH CC

  • Loose or wrong connection between the refrigerant sensor and PCB
  • Wrong ENC1 setting
  • Faulty refrigerant sensor

A technician checks these and 1 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Carrier models that use code FH CC

37MUHA37MURAD5FUAAH18AAKD5FUAAH24AAKD5FUAAH30AAKD5FUAAH36AAKD5FUAAH48AAKD5FUAAH60AAK

Other Carrier Heat Pump codes

CodeMeaning
EL0CSystem lacks refrigerant
EL 01Indoor and outdoor unit communication error
EL01IDU & ODU communication error
EL 16Communication malfunction between adapter board and outdoor main board
EL16Communication malfunction between adapter board and outdoor main board
FCForced cooling mode
FHCCRefrigerant sensor error
FL 09Mismatch between new and old platforms
FL09Mismatch between the new and old platforms
Forced defrostForced defrost (short the defrost pins)
LC 06Compressor top (IPM) temperature protection
LD1MOC red LED LD1 (sizes 25-60)

All Carrier Heat Pump error codes →

Carrier code FH CC: homeowner questions

What does Carrier code FH CC mean?

Refrigerant sensor error. The indoor unit receives a fault signal from the refrigerant sensor for 10 s, or it gets no feedback from the sensor for 150 s. The manual prints this code as FH CC; it may be a typo for EH CC.

Is it safe to keep using my heat pump with code FH CC?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Carrier code FH CC myself?

You can try one reset (power off for 30 seconds, then on). If Carrier code FH CC comes back, the cause is still there and a licensed technician should check it.

Who can fix Carrier code FH CC near me?

Aurora Star Tech Inc. repairs Carrier heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: D5FUAA service manual, p. 37. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977