Carrier Heat Pump: Wiring scenario 1: 24 V thermostat with RS485 between units
Wiring scenario 1: 24 V thermostat with RS485 between units on a Carrier heat pump: Preferred method. A 24 V thermostat is used with RS485 communication between indoor and outdoor units.
Applies to: Thermostat and indoor/outdoor wiring
How to fix wiring scenario 1: 24 v thermostat with rs485 between units: step by step
- Do not use the B and W terminals together.
- Use W only for a conventional thermostat heat demand.
- Do not use any outdoor unit 24 V terminals in this scenario.
- Leave DS unused; it is a reserve terminal.
- Wire the 24 V thermostat as shown in Fig. 30.
If the unit shows an error code, look it up: Carrier Heat Pump codes
Models
D5CURA + D5MUWAD5CURAH18AAKD5CURAH24AAKD5CURAH30AAKD5CURAH36AAKD5CURAH48AAKD5CURAH60AAK
Source: D5CURA installation manual, p. 28. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.