Carrier Heat Pump: Fan motor checks (indoor and outdoor DC fan motors)
Fan motor checks (indoor and outdoor DC fan motors) on a Carrier heat pump: Checks for the indoor and outdoor DC fan motors used in fan speed faults.
Applies to: D5FUAA indoor and outdoor fan motors
How to fix fan motor checks (indoor and outdoor dc fan motors): step by step
- Indoor DC fan motor (control chip is in the fan motor): with power on and unit in standby, measure the voltage from pin 1 to pin 3 and pin 4 to pin 3 at the fan motor connector. If not in the range in the pin table, replace the PCB.
- Outdoor DC fan motor (control chip is in the outdoor PCB): release the UVW connector and measure resistance U-V, U-W and V-W.
- If the resistances are not equal to each other, replace the fan motor.
- If the resistances are equal, replace the PCB.
If the unit shows an error code, look it up: Carrier Heat Pump codes
Models
37MUHA37MURAD5FUAAH18AAKD5FUAAH24AAKD5FUAAH30AAKD5FUAAH36AAKD5FUAAH48AAKD5FUAAH60AAK
Source: D5FUAA Service Manual, p. 26. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.