Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Carrier Heat Pump: Fan motor checks (indoor and outdoor DC fan motors)

Updated · by Aurora Star Tech Inc.

Fan motor checks (indoor and outdoor DC fan motors) on a Carrier heat pump: Checks for the indoor and outdoor DC fan motors used in fan speed faults.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: D5FUAA indoor and outdoor fan motors

How to fix fan motor checks (indoor and outdoor dc fan motors): step by step

  1. Indoor DC fan motor (control chip is in the fan motor): with power on and unit in standby, measure the voltage from pin 1 to pin 3 and pin 4 to pin 3 at the fan motor connector. If not in the range in the pin table, replace the PCB.
  2. Outdoor DC fan motor (control chip is in the outdoor PCB): release the UVW connector and measure resistance U-V, U-W and V-W.
  3. If the resistances are not equal to each other, replace the fan motor.
  4. If the resistances are equal, replace the PCB.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Carrier Heat Pump codes

Models

37MUHA37MURAD5FUAAH18AAKD5FUAAH24AAKD5FUAAH30AAKD5FUAAH36AAKD5FUAAH48AAKD5FUAAH60AAK

Source: D5FUAA Service Manual, p. 26. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.