Carrier Heat Pump: Crossover wiring to single or two stage furnace (KSAIC0701230 interface)

Updated · by Aurora Star Tech Inc.

Crossover wiring to single or two stage furnace (KSAIC0701230 interface) on a Carrier heat pump: Pairing an approved residential furnace with the D5CURA through the crossover interface. Only crossover outdoor units (D5CURA/D5CUHA) are compatible.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: D5CURA with approved furnaces via KSAIC0701230

How to fix crossover wiring to single or two stage furnace (ksaic0701230 interface): step by step

  1. Install the KSAIC0701230 crossover interface between the thermostat, furnace control and outdoor unit.
  2. Wire 24 VAC field wiring to the interface and the furnace leak dissipation board as shown on page 21.
  3. Make sure the heat pump has a high pressure switch for dual fuel use.
  4. Use a dual fuel thermostat. Simultaneous heat pump and furnace operation is not permitted.
  5. Do not use the W terminal on the interface for dual fuel use or where emergency heat is wanted.
  6. Do not use any 24 V terminals on the outdoor unit.
  7. The outdoor reversing valve still energizes in heat pump heating. Set the O to energize-in-cool logic so airflow matches Y1 and Y/Y2 demands.
  8. The furnace leak dissipation logic triggers a leak detection error on the interface display through the alarm input. Refer to the interface display for the code.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Carrier Heat Pump codes

Models

D5CURA + D5MUWAD5CURAH18AAKD5CURAH24AAKD5CURAH30AAKD5CURAH36AAKD5CURAH48AAKD5CURAH60AAK

Source: D5CURA installation manual, p. 21. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.