How to fix 30k/36k unit disassembly – panel removal: step by step

  1. Turn off the air conditioner and the power breaker.
  2. Remove the screw of the big handle, then remove the big handle (2 screws). One top cover screw sits under the big handle.
  3. Remove the top cover (4 screws, US models 3 screws).
  4. Remove the front right panel (2 screws).
  5. Remove the front panel (9 screws).
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Carrier Heat Pump codes

Models

D5CURA + D5MUWAD5CURAH18AAKD5CURAH24AAKD5CURAH30AAKD5CURAH36AAKD5CURAH48AAKD5CURAH60AAK

Source: D5CURA service manual, p. 71-72. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.