Carrier Error Code EC 56: Outdoor temperature sensor open or short (Heat Pump)

Updated · by Aurora Star Tech Inc.

Carrier error code EC 56 on a heat pump means: Outdoor temperature sensor open or short. It is also called Carrier diagnostic code EC 56.

Medium severityHeat PumpD5FUAA

Homeowner? What Carrier code EC 56 means for you

Check, then call Your heat pump is reporting: Outdoor temperature sensor open or short. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Carrier error code EC 56 mean?

The sampling voltage is below 0.06 V or above 4.94 V and the display shows the failure.

Applies to: D5FUAA outdoor unit

Common causes of Carrier code EC 56

  • Sensor open or shorted
  • Sensor wiring or connection to the PCB faulty
  • Outdoor PCB faulty
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Carrier models that use code EC 56

37MUHA37MURAD5FUAAH18AAKD5FUAAH24AAKD5FUAAH30AAKD5FUAAH36AAKD5FUAAH48AAKD5FUAAH60AAK

Other Carrier Heat Pump codes

CodeMeaning
EC52ODU coil temp sensor error
EC 53Outdoor temperature sensor open or short
EC53ODU ambient temp sensor error
EC 54Outdoor temperature sensor open or short
EC54COMP. discharge temp sensor error
EC 55Quick maintenance code (outdoor)
EC56IDU coil outlet temp sensor error
EC 57Quick maintenance code (outdoor)
ECC1Other IDU refrigerant sensor detects leakage (multi-zone)
EH 0AEEPROM malfunction (indoor unit)
EH0AIDU EEPROM parameter error
EH 0bIndoor main control board and display board communication error

All Carrier Heat Pump error codes →

Carrier code EC 56: homeowner questions

What does Carrier code EC 56 mean?

Outdoor temperature sensor open or short. The sampling voltage is below 0.06 V or above 4.94 V and the display shows the failure.

Is it safe to keep using my heat pump with code EC 56?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Carrier code EC 56 myself?

You can try one reset (power off for 30 seconds, then on). If Carrier code EC 56 comes back, the cause is still there and a licensed technician should check it.

Who can fix Carrier code EC 56 near me?

Aurora Star Tech Inc. repairs Carrier heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: D5FUAA Service Manual, p. 27. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977