Carrier 37MARAQ Error Codes
Carrier 37MARAQ error codes and diagnostic codes (also listed as Single zone outdoor unit). The 37MARAQ is a Carrier heat pump in the D5FCFA series.
Carrier 37MARAQ error codes list
| Code | Meaning | Severity |
|---|---|---|
| EC 51 | EEPROM malfunction (outdoor unit) | High |
| EH 0A | EEPROM malfunction (indoor unit) | High |
| EH 00 | EEPROM malfunction (indoor unit) | High |
| EH 03 | Indoor fan speed outside normal range | Medium |
Troubleshooting the 37MARAQ
- 2 flashes: HPS open ≥6 s; 3: discharge >263°F; 4: discharge <90°F after 1 h; 5: defrost failure; 6: discharge sensor short; 7: outdoor sensor open/short; 9: bonnet sensor fail All brands · Heat Pump
- Excess ice on outdoor coil All brands · Heat Pump
- Extremely high head pressure in heating (dual fuel) All brands · Heat Pump
- Insufficient heat in cold weather All brands · Heat Pump
- Liquid slugging / compressor damage in heating All brands · Heat Pump
- No mode change / wrong mode All brands · Heat Pump
- Odour at registers (dirty sock) All brands · Heat Pump
- Poor heating but OK cooling (or vice-versa) All brands · Heat Pump
- Service problem analysis (Amana chart excerpt) All brands · Heat Pump
- Subcooling too high All brands · Heat Pump
- Subcooling too low vs mfr target All brands · Heat Pump
- TXV bulb/diaphragm failure All brands · Heat Pump
- Water-source: coil freezing All brands · Heat Pump
- Won't change mode / both coils same temperature All brands · Heat Pump
- Wrong superheat after line-set change; poor capacity All brands · Heat Pump
- Amber STATUS or green COMM light not on Carrier · Heat Pump
- Connect the inverter test tool (Dr. SMART) to the outdoor unit Carrier · Heat Pump
- Defrost mode entry and exit Carrier · Heat Pump
- Delay before the compressor restarts Carrier · Heat Pump
- Discharge the electrolytic capacitor before troubleshooting Carrier · Heat Pump
- Electrical parts removal Carrier · Heat Pump
- Evacuation and fuse rules Carrier · Heat Pump
- Exit Inquiry Mode Carrier · Heat Pump
- Fan and motor removal Carrier · Heat Pump
- Flammable refrigerant R-454B handling Carrier · Heat Pump
- Front panel removal Carrier · Heat Pump
- Heat pump will not defrost - HK32EA defrost board Carrier · Heat Pump
- Noisy compressor or loud defrost shift - Carrier split systems Carrier · Heat Pump
- Outdoor ECM fan not running - Carrier 25HNB9/24ANB1 Carrier · Heat Pump
- Outdoor unit unresponsive after several faults Carrier · Heat Pump
- Outdoor unit will not run - HK32EA defrost board heat pumps Carrier · Heat Pump
- Parts to check for specific error codes Carrier · Heat Pump
- Power and communication wiring between outdoor and indoor unit Carrier · Heat Pump
- Prepare the control boards for voltage and signal checks Carrier · Heat Pump
- Reading the indoor unit error display Carrier · Heat Pump
- RS485 communication error between indoor and outdoor unit Carrier · Heat Pump
- Start diagnosis with the indoor unit display Carrier · Heat Pump
- Test DC voltage between communication ports and reactor resistance Carrier · Heat Pump
All Carrier Heat Pump error codes →
Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.