Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Carrier Error Code PC 02: Compressor top or IPM temperature protection (Heat Pump)

Updated · by Aurora Star Tech Inc.

Carrier error code PC 02 on a heat pump means: Compressor top or IPM temperature protection. It is also called Carrier diagnostic code PC 02.

High severityHeat PumpD5FUHA

Homeowner? What Carrier code PC 02 means for you

Call a technician Your heat pump is reporting: Compressor top or IPM temperature protection. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Carrier error code PC 02 mean?

Some models have overload protection. The code shows if the sampling voltage is not 5 V or if the IPM module temperature is above a set value. Prepare connection wires, outdoor PCB, IPM module board, high pressure protector, and check for system blockages.

Applies to: D5FUHA heat pump outdoor unit

Common causes of Carrier code PC 02

  • Blocked indoor or outdoor airflow
  • High compressor top temperature
  • Refrigerant system fault or blockage

A technician checks these and 2 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Carrier Heat Pump codes

CodeMeaning
PC0LLow ambient temp. protection
PC00ODU IPM module protection
PC 00Outdoor IPM module protection
PC01ODU voltage protection
PC 01Outdoor voltage protection
PC02Compressor top (or IPM) temp. protection
PC03Pressure protection (low or high pressure)
PC 03High or low pressure protection
PC04Inverter compressor drive error
PC 04Inverter compressor drive error
PC 06Quick maintenance code (outdoor)
PC 08Quick maintenance code (outdoor)

All Carrier Heat Pump error codes →

Carrier code PC 02: homeowner questions

What does Carrier code PC 02 mean?

Compressor top or IPM temperature protection. Some models have overload protection. The code shows if the sampling voltage is not 5 V or if the IPM module temperature is above a set value. Prepare connection wires, outdoor PCB, IPM module board, high pressure protector, and check for…

Is it safe to keep using my heat pump with code PC 02?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Carrier code PC 02 myself?

You can try one reset (power off for 30 seconds, then on). If Carrier code PC 02 comes back, the cause is still there and a licensed technician should check it.

Who can fix Carrier code PC 02 near me?

Aurora Star Tech Inc. repairs Carrier heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Carrier D5FUHA Service Manual, p. 35. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service