Carrier Heat Pump: Crossover wiring to single or two speed fan coil (KSAIC0701230 interface)
Crossover wiring to single or two speed fan coil (KSAIC0701230 interface) on a Carrier heat pump: Pairing an approved fan coil with the D5CURA through the crossover interface. Only crossover outdoor units (D5CURA/D5CUHA) are compatible.
Applies to: D5CURA with approved fan coils via KSAIC0701230
How to fix crossover wiring to single or two speed fan coil (ksaic0701230 interface): step by step
- Install the KSAIC0701230 crossover interface between the thermostat, fan coil control and outdoor unit.
- Wire 24 VAC field wiring to the interface and fan coil leak dissipation board as shown on page 22.
- Make sure the heat pump has a high pressure switch for dual fuel use.
- Use a dual fuel thermostat. Simultaneous heat pump and furnace operation is not permitted.
- Do not use any 24 V terminals on the outdoor unit.
- Do not use the W terminal on the interface for dual fuel use or where emergency heat is wanted.
- The outdoor reversing valve still energizes in heat pump heating. Set the O to energize-in-cool logic so airflow matches Y1 and Y/Y2 demands.
- The fan coil leak dissipation logic triggers a leak detection error on the interface display through the alarm input. Refer to the interface display for the code.
If the unit shows an error code, look it up: Carrier Heat Pump codes
Models
D5CURA + D5MUWAD5CURAH18AAKD5CURAH24AAKD5CURAH30AAKD5CURAH36AAKD5CURAH48AAKD5CURAH60AAK
Source: D5CURA installation manual, p. 22. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.