Carrier Heat Pump: Recovering refrigerant and decommissioning
Recovering refrigerant and decommissioning on a Carrier heat pump: Recovery and decommissioning steps for flammable refrigerant units.
Applies to: Refrigerant recovery
How to fix recovering refrigerant and decommissioning: step by step
- Confirm the technician knows the equipment and that electrical power is available.
- Isolate the system electrically.
- Pump down the system if possible; otherwise use a manifold to recover from several points.
- Place the recovery cylinder on scales before recovery.
- Do not fill cylinders above 80% liquid volume or exceed their maximum working pressure.
- Label the equipment as decommissioned and emptied, with date and signature, and mark it as containing flammable refrigerant.
- Do not reuse recovered refrigerant unless it has been cleaned and checked.
If the unit shows an error code, look it up: Carrier Heat Pump codes
Models
37MUHA37MURAD5FUAAH18AAKD5FUAAH24AAKD5FUAAH30AAKD5FUAAH36AAKD5FUAAH48AAKD5FUAAH60AAK
Source: D5FUAA Service Manual, p. 7. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.