Carrier Error Code PC 01: Outdoor voltage protection (Heat Pump)

Updated · by Aurora Star Tech Inc.

Carrier error code PC 01 on a heat pump means: Outdoor voltage protection. It is also called Carrier diagnostic code PC 01.

High severityHeat PumpD5FUHA

Homeowner? What Carrier code PC 01 means for you

Call a technician Your heat pump is reporting: Outdoor voltage protection. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Carrier error code PC 01 mean?

Abnormal rises or drops in voltage are detected by the voltage detection circuit. Recommended parts: power supply wires, IPM module board, PCB, reactor.

Applies to: D5FUHA

Common causes of Carrier code PC 01

  • Incorrect or unstable supply voltage
  • Faulty power supply wires or connections
  • Faulty IPM board

A technician checks these and 2 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Carrier Heat Pump codes

CodeMeaning
PC 0FQuick maintenance code (outdoor)
PC 0LLow ambient temperature protection
PC0LLow ambient temp. protection
PC00ODU IPM module protection
PC 00Outdoor IPM module protection
PC01ODU voltage protection
PC02Compressor top (or IPM) temp. protection
PC 02Compressor top or IPM temperature protection
PC03Pressure protection (low or high pressure)
PC 03High or low pressure protection
PC04Inverter compressor drive error
PC 04Inverter compressor drive error

All Carrier Heat Pump error codes →

Carrier code PC 01: homeowner questions

What does Carrier code PC 01 mean?

Outdoor voltage protection. Abnormal rises or drops in voltage are detected by the voltage detection circuit. Recommended parts: power supply wires, IPM module board, PCB, reactor.

Is it safe to keep using my heat pump with code PC 01?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Carrier code PC 01 myself?

You can try one reset (power off for 30 seconds, then on). If Carrier code PC 01 comes back, the cause is still there and a licensed technician should check it.

Who can fix Carrier code PC 01 near me?

Aurora Star Tech Inc. repairs Carrier heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: D5FUHA service manual, p. 31. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977