Carrier Heat Pump: Built-in protections and delays
Built-in protections and delays on a Carrier heat pump: The unit has a 3 minute compressor time delay, a 46°F heating setback, auto restart, auto changeover, low voltage and overload protection, compressor over current protection, high discharge temperature protection, and IPM module protection. Condenser high temperature protection in cooling mode is not marked as standard.
Applies to: D5CURA outdoor units
How to fix built-in protections and delays: step by step
- Allow the 3 minute compressor time delay to finish before judging a compressor restart.
- Check the power supply voltage if low voltage protection trips.
If the unit shows an error code, look it up: Carrier Heat Pump codes
Models
D5CURA + D5MUWAD5CURAH18AAKD5CURAH24AAKD5CURAH30AAKD5CURAH36AAKD5CURAH48AAKD5CURAH60AAK
Source: D5CURA Product Data, p. 3. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.