Carrier Error Code Forced defrost: Forced defrost (short the defrost pins) (Heat Pump)

Updated · by Aurora Star Tech Inc.

Carrier error code Forced defrost on a heat pump means: Forced defrost (short the defrost pins). It is also called Carrier diagnostic code Forced defrost.

Low severityHeat PumpCarrier single-stage communicating HP

Homeowner? What Carrier code Forced defrost means for you

Usually minor Your heat pump is reporting: Forced defrost (short the defrost pins). This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Carrier error code Forced defrost mean?

Test function that starts a defrost cycle by hand. A full defrost runs only if the coil is at 32 F / 0 C and the outdoor air is under 50 F / 10 C; otherwise only an abbreviated 30-second defrost happens. Quiet Shift-2 delays are included when that mode is on. The HK32EA003/008 defrost boards use a similar speed-up jumper (J1): short for 5 seconds then release; with the defrost thermostat open a short defrost of about 30 seconds results, with it closed a full cycle runs.

Applies to: Carrier single-stage communicating heat pump; HK32EA003/008 defrost boards

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Carrier Heat Pump codes

CodeMeaning
EL16Communication malfunction between adapter board and outdoor main board
FCForced cooling mode
FH CCRefrigerant sensor error
FHCCRefrigerant sensor error
FL 09Mismatch between new and old platforms
FL09Mismatch between the new and old platforms
LC 06Compressor top (IPM) temperature protection
LD1MOC red LED LD1 (sizes 25-60)
LD5MOC green LED LD5 (sizes 25-60)
LED1MOC red LED1 (sizes 25-60)
LED3MOC amber LED3 (sizes 25-60)
LED200MOC red LED (sizes 13, 24B)

All Carrier Heat Pump error codes →

Carrier code Forced defrost: homeowner questions

What does Carrier code Forced defrost mean?

Forced defrost (short the defrost pins). Test function that starts a defrost cycle by hand. A full defrost runs only if the coil is at 32 F / 0 C and the outdoor air is under 50 F / 10 C; otherwise only an abbreviated 30-second defrost happens. Quiet Shift-2 delays are included…

Is it safe to keep using my heat pump with code Forced defrost?

Usually yes. Code Forced defrost is normally minor, but if it keeps coming back have it checked.

Can I reset Carrier code Forced defrost myself?

You can try one reset (power off for 30 seconds, then on). If Carrier code Forced defrost comes back, the cause is still there and a licensed technician should check it.

Who can fix Carrier code Forced defrost near me?

Aurora Star Tech Inc. repairs Carrier heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Carrier residential A/C and heat pump service manual 24-25, Forced Defrost, p.48; HK32EA003/008 Defrost Control, p.17-18. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.