Rinnai Error Code 021: Too Long DHW Continuous Operation (Boiler)

Updated · by Aurora Star Tech Inc.

Rinnai error code 021 on a boiler means: Too Long DHW Continuous Operation. It is also called Rinnai diagnostic code 021.

Medium severityBoilerI-Series Plus

Homeowner? What Rinnai code 021 means for you

Check, then call Your boiler is reporting: Too Long DHW Continuous Operation. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Rinnai error code 021 mean?

Hot water (DHW) has been drawn longer than the maximum continuous run time allowed by parameter 18.

Applies to: I-Series Plus combi boiler

Common causes of Rinnai code 021

  • DHW used beyond the maximum continuous operating time set by parameter 18
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Rinnai Boiler codes

CodeMeaning
00-AParameter menu entry
60Descaling countdown (minutes remaining)
100Air intake/exhaust blockage or full condensate trap
110Ignition failure
120Flame failure (flame lost during operation)
140Overheat switch tripped (heat exchanger overheating)
150Venturi control fault
161High outgoing temperature
170Venturi blockage / position mismatch
180Gas valve air/fuel adjustment limit reached
190Electrical grounding / short in DC circuit
210Data transfer error

All Rinnai Boiler error codes →

Rinnai code 021: homeowner questions

What does Rinnai code 021 mean?

Too Long DHW Continuous Operation. Hot water (DHW) has been drawn longer than the maximum continuous run time allowed by parameter 18.

Is it safe to keep using my boiler with code 021?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Rinnai code 021 myself?

You can try one reset (power off for 30 seconds, then on). If Rinnai code 021 comes back, the cause is still there and a licensed technician should check it.

Who can fix Rinnai code 021 near me?

Aurora Star Tech Inc. repairs Rinnai boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Rinnai I-Series Plus IP060160C installation and operation manual, p. 113. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.