Rinnai Error Code 681: Hot Water Supply Temperature Abnormality (Combi Only) (Boiler)
Rinnai error code 681 on a boiler means: Hot Water Supply Temperature Abnormality (Combi Only). It is also called Rinnai diagnostic code 681.
Homeowner? What Rinnai code 681 means for you
Check, then call Your boiler is reporting: Hot Water Supply Temperature Abnormality (Combi Only). This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
- Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
- Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
- Check that the boiler gas valve is open (handle in line with the pipe).
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Rinnai error code 681 mean?
DHW temperature is above set point, usually because the bypass servo does not close.
Applies to: I-Series Plus combi boiler
Common causes of Rinnai code 681
- Bypass servo failed to close
- Bypass flow control faulty
- Inlet or heat exchanger thermistor wiring damaged
A technician checks these and 2 other possible causes on site before replacing any part.
Other Rinnai Boiler codes
All Rinnai Boiler error codes →
Rinnai code 681: homeowner questions
What does Rinnai code 681 mean?
Hot Water Supply Temperature Abnormality (Combi Only). DHW temperature is above set point, usually because the bypass servo does not close.
Is it safe to keep using my boiler with code 681?
It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.
Can I reset Rinnai code 681 myself?
You can try one reset (power off for 30 seconds, then on). If Rinnai code 681 comes back, the cause is still there and a licensed technician should check it.
Who can fix Rinnai code 681 near me?
Aurora Star Tech Inc. repairs Rinnai boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: Boiler Not Heating: What to Check
Troubleshooting guides
- Condensing/corrosion of conventional boiler All brands · Boiler
- No heat or some zones cold All brands · Boiler
- Noise All brands · Boiler
- Poor heat / circulation All brands · Boiler
- Relief valve weeps every cycle / pressure climbs All brands · Boiler
- Short cycling / wasted fuel All brands · Boiler
- Symptoms of air in system All brands · Boiler
- Uneven heating All brands · Boiler
- Won't fire All brands · Boiler
- Adjust the central heating setpoint temperature Rinnai · Boiler
- Adjust the DHW setpoint temperature Rinnai · Boiler
- Air filter cleaning Rinnai · Boiler
- Altitude and venting limits Rinnai · Boiler
- Annual maintenance checklist Rinnai · Boiler
- Annual maintenance checks Rinnai · Boiler
- Apply LPG conversion label Rinnai · Boiler
- Automatic de-aeration program (A xx, 17 min) Rinnai · Boiler
- Basic DHW piping arrangement Rinnai · Boiler
- Boiler Does Not Start Heating With a Heating Demand Rinnai · Boiler
- Boiler filling, air purge and commissioning Rinnai · Boiler
- Boiler that was under water Rinnai · Boiler
- Boost mode Rinnai · Boiler
- Burner flame visual inspection Rinnai · Boiler
- Cancel the descaling cycle Rinnai · Boiler
- Cannot Change the DHW Set Point (Combi Only) Rinnai · Boiler
- Cannot Set Up Lock Rinnai · Boiler
- Cannot Turn Off ECO Mode Rinnai · Boiler
- Carbon monoxide alarm before start-up Rinnai · Boiler
- Central heating common components Rinnai · Boiler
- Central heating return and supply connections Rinnai · Boiler
- Central heating works, no domestic hot water Rinnai · Boiler
- CH Capacity Is Insufficient Rinnai · Boiler
- Change a parameter in the PARA chapter Rinnai · Boiler
- Change altitude setting (parameter A3) Rinnai · Boiler
- Change altitude setting on the PC board Rinnai · Boiler
- Change display units (F/C) Rinnai · Boiler
- Change parameter A2 to allow higher exhaust temperatures Rinnai · Boiler
- Change the DHW setpoint temperature Rinnai · Boiler
- Check burner flame appearance Rinnai · Boiler
- Choose a vent termination location Rinnai · Boiler
- Choose a venting option (direct vent or non-direct vent) Rinnai · Boiler
- Choose an installation location Rinnai · Boiler
- Combustion air and venting checklist Rinnai · Boiler
- Combustion air requirements for confined and unconfined spaces Rinnai · Boiler
- Combustion analysis port access Rinnai · Boiler
- Common vent spillage test when a boiler is removed Rinnai · Boiler
- Condensate drain installation Rinnai · Boiler
- Condensate drain line installation Rinnai · Boiler
- Connect a Rinnai BLE push button Rinnai · Boiler
- Connect the condensate drain pipe Rinnai · Boiler
- Convert the boiler from natural gas to propane Rinnai · Boiler
- Correct gas type or venting after first setup Rinnai · Boiler
- Crossover mode recirculation setup Rinnai · Boiler
- Decreasing or Fluctuating DHW Water Flow (Combi Only) Rinnai · Boiler
- Dedicated mode recirculation setup and flow Rinnai · Boiler
- Descale the plate heat exchanger with vinegar and rinse Rinnai · Boiler
- DHW heat exchanger flush with vinegar Rinnai · Boiler
- DHW Recirculation Does Not Begin (Combi Only) Rinnai · Boiler
- DHW temperature drops Rinnai · Boiler
- Display diagnostic codes Rinnai · Boiler
- Do not bypass deaeration Rinnai · Boiler
- Do not install in restricted or unsafe areas Rinnai · Boiler
- Do not run without front panel and watch burn hazard Rinnai · Boiler
- Domestic hot water expansion control Rinnai · Boiler
- Domestic hot water plumbing connections Rinnai · Boiler
- Enable simultaneous central heating and domestic hot water Rinnai · Boiler
- End deaeration and return to normal operation Rinnai · Boiler
- Enter and exit parameter settings using SW1 left button Rinnai · Boiler
- Enter parameter setting mode on the PC board Rinnai · Boiler
- Enter parameter settings from the PC board Rinnai · Boiler
- Enter parameter settings mode Rinnai · Boiler
- External pump and multi-thermostat zone wiring Rinnai · Boiler
- Fill the condensate collector before operation and before venting Rinnai · Boiler
- Fill the condensate trap before startup Rinnai · Boiler
- First-time settings using Bluetooth (recommended) Rinnai · Boiler
- Fluctuating DHW Outgoing Temperature (Combi Only) Rinnai · Boiler
- Force the burner on for combustion checks (SERV function 1) Rinnai · Boiler
- Forced high and forced low fire test modes Rinnai · Boiler
- Gas conversion safety precautions Rinnai · Boiler
- Gas odor response Rinnai · Boiler
- Gas pipe sizing worked example Rinnai · Boiler
- Gas supply connection and leak check Rinnai · Boiler
- Gas supply pressure testing Rinnai · Boiler
- Glycol antifreeze check Rinnai · Boiler
- Hard water and DHW scale Rinnai · Boiler
- Heating system warms without a call Rinnai · Boiler
- Hot water works, no central heating Rinnai · Boiler
- Hydraulic separation and primary/secondary piping Rinnai · Boiler
- Ignition safety test (forced E02 lockout) Rinnai · Boiler
- Install and wire a remote temperature controller Rinnai · Boiler
- Install concentric vent pipe and termination Rinnai · Boiler
- Install the outdoor temperature sensor for outdoor reset Rinnai · Boiler
- Installation completion checklist Rinnai · Boiler
- Installer qualifications Rinnai · Boiler
- Installer qualifications and warranty Rinnai · Boiler
- Insufficient hot water quantity Rinnai · Boiler
- Isolate power, gas and water before maintenance Rinnai · Boiler
- Keep corrosive compounds away from combustion air Rinnai · Boiler
- Manual CH plumbing flush and purge Rinnai · Boiler
- Massachusetts requirements for side wall horizontal gas venting Rinnai · Boiler
- MC-601 priority during technician work Rinnai · Boiler
- Monthly owner maintenance checks Rinnai · Boiler
- Mount the boiler to the wall Rinnai · Boiler
- Nothing Happens When DHW Water Flow Is Activated (Combi Only) Rinnai · Boiler
- Open the installer level (code C123) Rinnai · Boiler
- Open the parameter settings menu on the PC board Rinnai · Boiler
- Outdoor vent cap not permitted Rinnai · Boiler
- Overheating or gas shutoff failure Rinnai · Boiler
- Pair the boiler with the Rinnai Central app over Bluetooth Rinnai · Boiler
- Parameter changes need trained technician Rinnai · Boiler
- Piping with refrigeration, air handler coils and multiple zones Rinnai · Boiler
- Power and fill rules before first firing Rinnai · Boiler
- Power supply and grounding requirements Rinnai · Boiler
- Pre-power wiring checklist Rinnai · Boiler
- Pressure relief valve installation Rinnai · Boiler
- Prime condensate trap before first firing Rinnai · Boiler
- Program cascade communication and secondary IDs Rinnai · Boiler
- Pump lock check Rinnai · Boiler
- Pump or Fan Runs With No Demand Rinnai · Boiler
- Radiators not hot enough or slow to heat Rinnai · Boiler
- Read the technical read-out and error history Rinnai · Boiler
- Reset diagnostic codes Rinnai · Boiler
- Reset Service Soon (SS) indicator Rinnai · Boiler
- Reset the SERVICE reminder (8000 h counter) Rinnai · Boiler
- Reset the Service Soon (SS) indicator Rinnai · Boiler
- Restore factory parameters (Copy) Rinnai · Boiler
- Room air combustion air vent installation Rinnai · Boiler
- Room air corrosive environment restrictions Rinnai · Boiler
- Room air installation sequence Rinnai · Boiler
- Room air multiple boiler vertical termination Rinnai · Boiler
- Room air vent piping configurations Rinnai · Boiler
- Scald risk at domestic hot water temperatures Rinnai · Boiler
- Set up DHW recirculation through the PC board Rinnai · Boiler
- Simultaneous DHW and CH Is Not Functional (Combi Only) Rinnai · Boiler
- Start deaeration on the PC board Rinnai · Boiler
- Substitute parts and electrical extension cords Rinnai · Boiler
- Supply Temperature Differs From Controller Setting Rinnai · Boiler
- SW3 button on PC board for descaling mode Rinnai · Boiler
- SW3 button starts and exits descaling mode Rinnai · Boiler
- Switch DHW comfort mode (Eco or Comfort) Rinnai · Boiler
- Test the condensate pump safety switch Rinnai · Boiler
- Test the ignition safety shutoff device Rinnai · Boiler
- Testing a common vent when removing an existing boiler Rinnai · Boiler
- Turn child lock on or off Rinnai · Boiler
- Turn gas on or off to the appliance Rinnai · Boiler
- Turn the control panel click sound on or off Rinnai · Boiler
- Twin pipe elbow selection Rinnai · Boiler
- Twin pipe horizontal and vertical termination layout Rinnai · Boiler
- Twin pipe vent installation sequence Rinnai · Boiler
- Vent material and solvent rules Rinnai · Boiler
- Vent termination location rules Rinnai · Boiler
- Venting general guidelines Rinnai · Boiler
- Venting slope and pressure plane rules Rinnai · Boiler
- Venturi reset on the PC board (code 170) Rinnai · Boiler
- View boiler performance data Rinnai · Boiler
- View the last nine error codes (DHW + Up) Rinnai · Boiler
- Wall strength Rinnai · Boiler
- Water fill and flushing rules Rinnai · Boiler
- Water quality and snow check Rinnai · Boiler
- When primary/secondary piping is required Rinnai · Boiler
- Wire DHW recirculation pump Rinnai · Boiler
- Wire the air handler output (OPU) to the boiler Rinnai · Boiler
- Wire the cascade cables Rinnai · Boiler
- Wire the condensate pump safety switch Rinnai · Boiler
Source: Rinnai I-Series Plus IP060160C installation and operation manual, p. 116. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.