Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Navien Error Code E788: Incorrect gas type setting (Combi Boiler)

Updated · by Aurora Star Tech Inc.

Navien error code E788 on a combi boiler means: Incorrect gas type setting. It is also called Navien diagnostic code E788.

Critical severityCombi BoilerNavien NCB-H · Navien NFC-H

Homeowner? What Navien code E788 means for you

Stop and call Your combi boiler is reporting: Incorrect gas type setting. This code is a safety shutdown. Turn the combi boiler off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Navien error code E788 mean?

The gas type setting does not match the PCB DIP switch. NFC-H lists it as abnormal gas setting, cleared through the Start-up Wizard. NFC-H manual lists the reset type as: Manual reset (Start-up Wizard).

Applies to: Navien fire-tube combi boilers, NFC-H series (NFC-250/200H, NFC-250/175H) and NCB-H combi boilers (NCB-250/150H, NCB-240/130H, NCB-240/110H, NCB-190/080H, NCB-190/060H)

Common causes of Navien code E788

  • Start-up Wizard gas type not matching DIP SW2 #1
  • Wrong DIP switch setting
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Navien models that use code E788

NCB-190/060HNCB-190/080HNCB-240/110HNCB-240/130HNCB-250/150HNFC-250/175HNFC-250/200H

Other Navien Combi Boiler codes

CodeMeaning
E762Vent pipe not fully inserted (VID)
E773Improper gas type detected
E777Low water cutoff (LWCO) activated
E782Front panel communication fault
E784Zone controller communication fault
E786Improper front panel
Exhaust TempStatus Information item 24 - Exhaust Temp
Fan Current APSStatus Information item 21 - Fan Current APS
Fan Current RPMStatus Information item 19 - Fan Current RPM
Fan Target APSStatus Information item 20 - Fan Target APS
Fan Target RPMStatus Information item 18 - Fan Target RPM
Flame ValueStatus Information item 17 - Flame Value

All Navien Combi Boiler error codes →

Navien code E788: homeowner questions

What does Navien code E788 mean?

Incorrect gas type setting. The gas type setting does not match the PCB DIP switch. NFC-H lists it as abnormal gas setting, cleared through the Start-up Wizard. NFC-H manual lists the reset type as: Manual reset (Start-up Wizard).

Is it safe to keep using my combi boiler with code E788?

No. Code E788 is a safety shutdown, so keep the combi boiler off until a licensed technician has checked it.

Can I reset Navien code E788 myself?

Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.

Who can fix Navien code E788 near me?

Aurora Star Tech Inc. repairs Navien combi boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Tankless Water Heater No Hot Water: What to Check · Boiler Not Heating: What to Check

Troubleshooting guides

Source: Navien NCB-H Installation & Operation Manual, 11.7 Understanding Error Codes, p.129-130; Navien NFC-H Installation Manual, 11.7 Understanding Error Codes, p.127-128. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service