Navien Air Conditioner: Outdoor coil high-temperature protection (T3)

Updated · by Aurora Star Tech Inc.

Outdoor coil high-temperature protection (T3) on a Navien air conditioner: If T3 goes above the maximum set temperature of 147 F (64 C), the unit stops and waits until T3 falls to the recovery point. The unit restarts when T3 drops below the set recovery temperature of 135 F (57 C).

Homeowner with a air conditioner problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NAA outdoor unit

Common causes of outdoor coil high-temperature protection (t3)

  • Outdoor coil running too hot, often from poor airflow or heat load at the condenser

How to fix outdoor coil high-temperature protection (t3): step by step

  1. Check outdoor coil and fan for blockage or poor airflow.
  2. Confirm T3 reading on the parameter check table.
  3. Restart is automatic once T3 falls below 135 F (57 C).
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Air Conditioner codes

Source: Navien NAA air conditioner service manual, p. 17. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.