Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Navien Error Code LO: Charging mode: outdoor air too cold (AC)

Updated · by Aurora Star Tech Inc.

Navien error code LO on a air conditioner means: Charging mode: outdoor air too cold. It is also called Navien diagnostic code LO.

Low severityAir ConditionerNavien NAE

Homeowner? What Navien code LO means for you

Usually minor Your air conditioner is reporting: Charging mode: outdoor air too cold. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Keep about 2 feet around the outdoor unit clear of leaves, grass and debris.
  • If you see ice on the pipes or the indoor coil, turn the system off and run only the fan for a few hours, then call a technician.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Navien error code LO mean?

Refrigerant charging mode. Outdoor air is below 55 F. The display flashes 3 seconds and the unit stops.

Applies to: NAE28V3622A1, NAE28V6022A1

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Navien models that use code LO

NAE28V3622A1NAE28V6022A1

Other Navien AC codes

CodeMeaning
LACompressor speed held back by voltage
LBCompressor speed held back by high pressure
LCCompressor speed held back by condenser temperature
LDCompressor speed held back by discharge temperature
LECompressor speed held back by drive module temperature
LFCompressor speed held back by current
P1High pressure switch opened
P2Low pressure protection
P3Compressor drive overcurrent
P4Discharge temperature too high
P5Condenser coil (T3) temperature too high - cooling
P6Compressor drive (IPM) module protection

All Navien Air Conditioner error codes →

Navien code LO: homeowner questions

What does Navien code LO mean?

Charging mode: outdoor air too cold. Refrigerant charging mode. Outdoor air is below 55 F. The display flashes 3 seconds and the unit stops.

Is it safe to keep using my air conditioner with code LO?

Usually yes. Code LO is normally minor, but if it keeps coming back have it checked.

Can I reset Navien code LO myself?

You can try one reset (power off for 30 seconds, then on). If Navien code LO comes back, the cause is still there and a licensed technician should check it.

Who can fix Navien code LO near me?

Aurora Star Tech Inc. repairs Navien air conditioners in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check

Troubleshooting guides

Source: Navien NAE I&O manual (07/2026), 3.2 LCD screen display, p.32-33. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977