Navien Error Code E027: Air pressure sensor fault (Combi Boiler)

Updated · by Aurora Star Tech Inc.

Navien error code E027 on a combi boiler means: Air pressure sensor fault. It is also called Navien diagnostic code E027.

Medium severityCombi BoilerNavien CH ASME

Homeowner? What Navien code E027 means for you

Check, then call Your combi boiler is reporting: Air pressure sensor fault. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
  • If only hot water is missing, check that the hot water tap is open far enough to start the heater.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Navien error code E027 mean?

The air pressure sensor is not reading right.

Applies to: Navien CH-180 / CH-210 / CH-240 ASME combi boilers

Common causes of Navien code E027

  • Blocked exhaust or intake pipe
  • Dirty intake air filter
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Navien models that use code E027

CH-180 ASMECH-210 ASMECH-240 ASME

Other Navien Combi Boiler codes

CodeMeaning
E015PCB fault
E016Heat exchanger overheat (overheating of heat exchanger)
E018Heating return sensor open
E019Heating return sensor shorted
E021DHW cold inlet sensor open
E022DHW cold inlet sensor shorted
E028Leak on the heating side
E030Exhaust overheat (abnormal exhaust temperature)
E031Burner overheat
E035Gas pressure sensor fault
E036Communication failure
E037Water leak inside the unit

All Navien Combi Boiler error codes →

Navien code E027: homeowner questions

What does Navien code E027 mean?

Air pressure sensor fault. The air pressure sensor is not reading right.

Is it safe to keep using my combi boiler with code E027?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Navien code E027 myself?

You can try one reset (power off for 30 seconds, then on). If Navien code E027 comes back, the cause is still there and a licensed technician should check it.

Who can fix Navien code E027 near me?

Aurora Star Tech Inc. repairs Navien combi boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Tankless Water Heater No Hot Water: What to Check · Boiler Not Heating: What to Check

Troubleshooting guides

Source: Navien CH ASME User's Operation Manual (ch-asme-operation-manual-en), Error Code Guide, p.43. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service