145 Navien Air Conditioner error codes and diagnostic codes, with causes and troubleshooting steps for each. Select a code, or find your model below.

Homeowner with a air conditioner problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Navien Air Conditioner error codes list

CodeMeaningSeverity
A251Alarm: PD high pressure protectionMedium
A252Alarm: PS low pressure protectionMedium
A253Alarm: TD discharge temperature protectionMedium
A254Alarm: CR compression ratio protectionMedium
A255Alarm: CUR overcurrent protectionMedium
A256Alarm: heatsink protectionMedium
A257Alarm: compressor temperature abnormal protectionMedium
A258Alarm: TS suction temperature protectionMedium
A259Alarm: superheat protectionMedium
A260Alarm: high pressure switch (HPS) protectionMedium
A851Inverter trip alarm: Communication errorMedium
A852Inverter trip alarm: Compressor current sensor errorMedium
A853Inverter trip alarm: DC link sensor errorMedium
A854Inverter trip alarm: PFCM current A errorMedium
A855Inverter trip alarm: PFCM current B errorMedium
A856Inverter trip alarm: Input voltage sensor errorMedium
A857Inverter trip alarm: Software compressor overcurrentMedium
A858Inverter trip alarm: Overcurrent at compressor current limitMedium
A859Inverter trip alarm: Overcurrent at ID current limitMedium
A860Inverter trip alarm: Hardware compressor overcurrentMedium
A861Inverter trip alarm: PFC overcurrentMedium
A862Inverter trip alarm: Estimator faultMedium
A863Inverter trip alarm: Compressor starting errorMedium
A864Inverter trip alarm: Wire miss errorMedium
A865Inverter trip alarm: Heatsink over temperatureMedium
A866Inverter trip alarm: DC under voltageMedium
A867Inverter trip alarm: DC over voltageMedium
A868Inverter trip alarm: AC under voltageMedium
A869Inverter trip alarm: AC over voltageMedium
A870Inverter trip alarm: PFC unbalanced currentMedium
A871Inverter trip alarm: Fan motor error (5 min)Medium
A872Inverter trip alarm: Discharge FET errorMedium
A873Inverter trip alarm: Stator overheat (5 min)Medium
A874Inverter trip alarm: PBA (power board) over temperatureMedium
ATLOutdoor temperature outside operating rangeMedium
d0Oil return cycleLow
dCForced coolingLow
E201High pressure (PD) protection errorHigh
E202Low pressure (PS) protection errorHigh
E203Compressor discharge temperature (TD) protection errorHigh
E204Compression ratio (CR) protection errorHigh
E205Overcurrent (CUR) protection errorHigh
E206Heatsink protection errorHigh
E207Compressor temperature abnormal errorHigh
E208Compressor suction temperature (TS) protection errorHigh
E209Superheat protection errorHigh
E210High pressure switch (HPS) protection errorHigh
E501Outdoor temperature sensor (Ta) open/shortMedium
E505Compressor discharge temperature sensor (TD) open/shortMedium
E506Compressor suction temperature sensor (TS) open/shortMedium
E507Condenser outlet temperature sensor (Tcond) open/shortMedium
E561Discharge pressure sensor (PD) open/shortMedium
E562Suction pressure sensor (PS) open/shortMedium
E702Outdoor unit to inverter driver communication failureHigh
E801Inverter trip: Communication errorHigh
E802Inverter trip: Compressor current sensor errorHigh
E803Inverter trip: DC link sensor errorHigh
E804Inverter trip: PFCM current A errorHigh
E805Inverter trip: PFCM current B errorHigh
E806Inverter trip: Input voltage sensor errorHigh
E807Inverter trip: Software compressor overcurrentHigh
E808Inverter trip: Overcurrent at compressor current limitHigh
E809Inverter trip: Overcurrent at ID current limitHigh
E810Inverter trip: Hardware compressor overcurrentHigh
E811Inverter trip: PFC overcurrentHigh
E812Inverter trip: Estimator faultHigh
E813Inverter trip: Compressor starting errorHigh
E814Inverter trip: Wire miss errorHigh
E815Inverter trip: Heatsink over temperatureHigh
E816Inverter trip: DC under voltageHigh
E817Inverter trip: DC over voltageHigh
E818Inverter trip: AC under voltageHigh
E819Inverter trip: AC over voltageHigh
E820Inverter trip: PFC unbalanced currentHigh
E821Inverter trip: Fan motor error (5 min)High
E822Inverter trip: Discharge FET errorHigh
E823Inverter trip: Stator overheat (5 min)High
E824Inverter trip: PBA (power board) over temperatureHigh
E999Error of unknown causeHigh
F0Communication fault (outdoor unit)High
F1Low pressure switch faultHigh
F4T4 outdoor ambient sensor faultMedium
F5T5 compressor discharge sensor faultMedium
F6T3 condenser coil sensor faultMedium
F7T7 sensor faultMedium
F8T7 sensor: condensate risk on the cooling plateMedium
F9Line voltage too low or too highHigh
FAOutdoor board memory (EEPROM) faultHigh
FBDrive chip memory (EEPROM) faultHigh
FCDrive module temperature sensor faultHigh
FDPressure sensor not detectedHigh
FET3 or T5 probe out of positionMedium
FFHigh pressure switch reads open all the timeHigh
H0Communication fault between chips on the outdoor PCBHigh
H1Lockout: outdoor coil too hot (P5 repeated)High
H2Lockout: high pressure switch (P1 repeated)High
H3High pressure abnormal (sensor over 3.6 MPa) - heating modeHigh
H4Lockout: drive module overheating (P8 repeated)High
H5Lockout: low pressure (P2 repeated)High
H6Lockout: high discharge temperature (P4 repeated)High
H7Lockout: low discharge superheat (PC repeated)High
H8Lockout: T3 probe off the pipe (FE repeated)High
HCLockout: discharge probe off the pipe (FE repeated)High
HERepeated condensate-risk faults (F8)Medium
HICharging mode: outdoor air too hotLow
L0DC bus voltage too lowHigh
L1DC bus voltage too highHigh
LACompressor speed held back by voltageLow
LBCompressor speed held back by high pressureLow
LCCompressor speed held back by condenser temperatureLow
LDCompressor speed held back by discharge temperatureLow
LECompressor speed held back by drive module temperatureLow
LFCompressor speed held back by currentLow
LOCharging mode: outdoor air too coldLow
P1High pressure switch openedHigh
P2Low pressure protectionHigh
P3Compressor drive overcurrentHigh
P4Discharge temperature too highHigh
P5Condenser coil (T3) temperature too high - coolingHigh
P6Compressor drive (IPM) module protectionCritical
P8Drive module (IPM) overheatingHigh
P9Outdoor fan motor faultHigh
PCLow discharge superheat (liquid floodback risk)High
PC, H7Moisture exposure error (overheat, T5-T3 under 9°F / 5°C)High
PDHigh pressure too highHigh
PRHCrankcase heater warm-up, no start yetLow
R101Condenser heat exchange abnormal alarmLow
R301Supply solenoid valve stuck alarmLow
R302Drain solenoid valve stuck alarmLow
R303Water supply abnormality alarmLow
R563Water pressure sensor open/short alarmLow
R601EEPROM alarmLow
R602NOR flash alarmLow
R881Inverter minor: IPM temperature sensor errorLow
R882Inverter minor: PFCM temperature sensor errorLow
R883Inverter minor: ID current limit minorLow
R884Inverter minor: Compressor current limit minorLow
R885Inverter minor: AC over voltageLow
R886Inverter minor: PFC overcurrentLow
R887Inverter minor: Input current limitLow
ST.10StandbyLow
ST.20Initial startupLow
ST.30Normal operationLow
ST.40Post-stop delayLow
THCharging mode: no thermostat callLow

Find codes by Navien model

Navien NAA

NAA17V36NAA17V60

Navien NAE

NAE28V3622A1NAE28V6022A1

Air Conditioner troubleshooting guides

Homeowner help: AC Running But Not Cooling: What to Check

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.