Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Navien Error Code LE: Compressor speed held back by drive module temperature (Heat Pump)

Updated · by Aurora Star Tech Inc.

Navien error code LE on a heat pump means: Compressor speed held back by drive module temperature. It is also called Navien diagnostic code LE.

Low severityHeat PumpNavien NAZ

Homeowner? What Navien code LE means for you

Usually minor Your heat pump is reporting: Compressor speed held back by drive module temperature. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Navien error code LE mean?

Status only. The board is limiting compressor speed because of drive module temperature. Nothing is broken.

Applies to: NAZ17V36 (24K/36K), NAZ17V60 (48K/60K)

Common causes of Navien code LE

  • Normal protection: drive module temperature near its limit
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Navien models that use code LE

NAZ17V36NAZ17V60

Other Navien Heat Pump codes

CodeMeaning
L0DC bus voltage too low
L1DC bus voltage too high
LACompressor speed held back by voltage
LBCompressor speed held back by high pressure
LCCompressor speed held back by condenser temperature
LDCompressor speed held back by discharge temperature
LFCompressor speed held back by current
P1High pressure switch opened
P2Low pressure protection
P3Compressor drive overcurrent
P4Discharge temperature too high
P5Outdoor coil too hot in cooling

All Navien Heat Pump error codes →

Navien code LE: homeowner questions

What does Navien code LE mean?

Compressor speed held back by drive module temperature. Status only. The board is limiting compressor speed because of drive module temperature. Nothing is broken.

Is it safe to keep using my heat pump with code LE?

Usually yes. Code LE is normally minor, but if it keeps coming back have it checked.

Can I reset Navien code LE myself?

You can try one reset (power off for 30 seconds, then on). If Navien code LE comes back, the cause is still there and a licensed technician should check it.

Who can fix Navien code LE near me?

Aurora Star Tech Inc. repairs Navien heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Navien NAZ Series Heat Pump Service Manual (V1.00), 4.2.21, p.54. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.