Navien Error Code E003: Ignition failure (Combi Boiler)
Navien error code E003 on a combi boiler means: Ignition failure. It is also called Navien diagnostic code E003.
Homeowner? What Navien code E003 means for you
Call a technician Your combi boiler is reporting: Ignition failure. The combi boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
- Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
- Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
- Check that the boiler gas valve is open (handle in line with the pipe).
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
- If only hot water is missing, check that the hot water tap is open far enough to start the heater.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Navien error code E003 mean?
The burner did not light (no flame proven) during the ignition attempts. NFC-H manual lists the reset type as: Manual reset.
Applies to: Navien fire-tube combi boilers, NFC-H series (NFC-250/200H, NFC-250/175H) and NCB-H combi boilers (NCB-250/150H, NCB-240/130H, NCB-240/110H, NCB-190/080H, NCB-190/060H)
Common causes of Navien code E003
- Main gas supply valve closed or gas supply interrupted
- Inlet gas pressure out of range
- Wrong gas type / orifice for the gas supplied
A technician checks these and 1 other possible causes on site before replacing any part.
Navien models that use code E003
NCB-190/060HNCB-190/080HNCB-240/110HNCB-240/130HNCB-250/150HNFC-250/175HNFC-250/200H
Other Navien Combi Boiler codes
All Navien Combi Boiler error codes →
Navien code E003: homeowner questions
What does Navien code E003 mean?
Ignition failure. The burner did not light (no flame proven) during the ignition attempts. NFC-H manual lists the reset type as: Manual reset.
Is it safe to keep using my combi boiler with code E003?
It depends on the cause. The combi boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.
Can I reset Navien code E003 myself?
You can try one reset (power off for 30 seconds, then on). If Navien code E003 comes back, the cause is still there and a licensed technician should check it.
Who can fix Navien code E003 near me?
Aurora Star Tech Inc. repairs Navien combi boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: Tankless Water Heater No Hot Water: What to Check · Boiler Not Heating: What to Check
Troubleshooting guides
- Annual maintenance check Navien · Combi Boiler
- CH series breaker trips or remote has no power Navien · Combi Boiler
- CH series cleaning the intake air filter Navien · Combi Boiler
- CH series E001 boiling in heat exchanger - full check Navien · Combi Boiler
- CH series E002 low water pressure / auto fill - full check Navien · Combi Boiler
- CH series E003 ignition failure - full check Navien · Combi Boiler
- CH series E004 false flame - full check Navien · Combi Boiler
- CH series E005 / E006 heating supply thermistor - full check Navien · Combi Boiler
Source: Navien NCB-H Installation & Operation Manual, 11.7 Understanding Error Codes, p.129-130; Navien NFC-H Installation Manual, 11.7 Understanding Error Codes, p.127-128. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.