Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Navien Error Code 110: Power board overheat (General)

Updated · by Aurora Star Tech Inc.

Navien error code 110 on a general means: Power board overheat. It is also called Navien diagnostic code 110.

High severityGeneralWEC

Homeowner? What Navien code 110 means for you

Call a technician Your heating or cooling system is reporting: Power board overheat. The heating or cooling system has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Navien error code 110 mean?

The power board is overheating.

Applies to: WEC600

Common causes of Navien code 110

  • Overheating of the power board
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Navien General codes

CodeMeaning
098CIP pump electronics fault
099Circulation pump valve electronics fault
100Anti-freezing valve electronics fault
105Abnormal RTC
106Abnormal panel key
107Abnormal EEPROM
111Over voltage at DC-Link
112Over current at converter
113Over current at module
114Over current at module
115IGBT error
116Over voltage inverter

All Navien General error codes →

Navien code 110: homeowner questions

What does Navien code 110 mean?

Power board overheat. The power board is overheating.

Is it safe to keep using my heating or cooling system with code 110?

It depends on the cause. The heating or cooling system has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Navien code 110 myself?

You can try one reset (power off for 30 seconds, then on). If Navien code 110 comes back, the cause is still there and a licensed technician should check it.

Who can fix Navien code 110 near me?

Aurora Star Tech Inc. repairs Navien heating or cooling systems in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Troubleshooting guides

Source: Navien WEC service manual, p. 57. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.