Navien Error Code E048: Low LP gas pressure (propane models) (Combi Boiler)

Updated · by Aurora Star Tech Inc.

Navien error code E048 on a combi boiler means: Low LP gas pressure (propane models). It is also called Navien diagnostic code E048.

High severityCombi BoilerNavien CH ASME

Homeowner? What Navien code E048 means for you

Call a technician Your combi boiler is reporting: Low LP gas pressure (propane models). The combi boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
  • If only hot water is missing, check that the hot water tap is open far enough to start the heater.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Navien error code E048 mean?

On propane units the board flags E048 when the gas pressure sensor sees LP pressure out of range. The unit needs a manual reset once the supply is fixed.

Applies to: Navien CH-180, CH-210, CH-240 and CH-240 ASME combi boilers

Common causes of Navien code E048

  • LP tank low or empty
  • LP supply pressure too low (often in winter)
  • Gas pressure sensor (GPS) or its hose faulty
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Navien models that use code E048

CH-180 ASMECH-210 ASMECH-240 ASME

Other Navien Combi Boiler codes

CodeMeaning
E036Communication failure
E037Water leak inside the unit
E039Flow sensor fault
E040Outdoor sensor shorted
E046Heat exchanger thermistor / overheat sensor fault
E047Exhaust thermistor fault
E060Dual venturi fault
E109Fan motor fault
E110Exhaust blockage / abnormal air pressure (APS)
E205Heating supply temperature sensor fault
E218Heating return temperature sensor fault
E278External (system) supply sensor not detected

All Navien Combi Boiler error codes →

Navien code E048: homeowner questions

What does Navien code E048 mean?

Low LP gas pressure (propane models). On propane units the board flags E048 when the gas pressure sensor sees LP pressure out of range. The unit needs a manual reset once the supply is fixed.

Is it safe to keep using my combi boiler with code E048?

It depends on the cause. The combi boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Navien code E048 myself?

You can try one reset (power off for 30 seconds, then on). If Navien code E048 comes back, the cause is still there and a licensed technician should check it.

Who can fix Navien code E048 near me?

Aurora Star Tech Inc. repairs Navien combi boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Tankless Water Heater No Hot Water: What to Check · Boiler Not Heating: What to Check

Troubleshooting guides

Source: Navien CH Series Service Manual (CH-180/210/240/240 ASME, 1st ed. July 2010, No. 20A-GT-002), 5.1 Error Code List p.55; 4.6.12 GPS p.43. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.