Navien Error Code FE: T3 or T5 probe out of position (Heat Pump)

Updated · by Aurora Star Tech Inc.

Navien error code FE on a heat pump means: T3 or T5 probe out of position. It is also called Navien diagnostic code FE.

Medium severityHeat PumpNavien NAZ

Homeowner? What Navien code FE means for you

Check, then call Your heat pump is reporting: T3 or T5 probe out of position. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Navien error code FE mean?

The board thinks the coil (T3) or discharge (T5) probe is not on the pipe.

Applies to: NAZ17V36 (24K/36K), NAZ17V60 (48K/60K)

Common causes of Navien code FE

  • T3 or T5 probe fell off or was moved
  • Damaged sensor
  • Outdoor PCB fault
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Navien models that use code FE

NAZ17V36NAZ17V60

Other Navien Heat Pump codes

CodeMeaning
F8T7 sensor: condensate risk on the cooling plate
F9Line voltage too low or too high
FAOutdoor board memory (EEPROM) fault
FBDrive chip memory (EEPROM) fault
FCDrive module temperature sensor fault
FDPressure sensor not detected
FFHigh pressure switch reads open all the time
H0Communication fault between chips on the outdoor PCB
H1Lockout: outdoor coil too hot (P5 repeated)
H2Lockout: high pressure switch (P1 repeated)
H3Lockout: high pressure in heating (PD repeated)
H4Lockout: drive module overheating (P8 repeated)

All Navien Heat Pump error codes →

Navien code FE: homeowner questions

What does Navien code FE mean?

T3 or T5 probe out of position. The board thinks the coil (T3) or discharge (T5) probe is not on the pipe.

Is it safe to keep using my heat pump with code FE?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Navien code FE myself?

You can try one reset (power off for 30 seconds, then on). If Navien code FE comes back, the cause is still there and a licensed technician should check it.

Who can fix Navien code FE near me?

Aurora Star Tech Inc. repairs Navien heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Navien NAZ Series Heat Pump Service Manual (V1.00), 4.2.7, p.33. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.