Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Navien Error Code H8: Lockout: T3 probe off the pipe (FE repeated) (AC)

Updated · by Aurora Star Tech Inc.

Navien error code H8 on a air conditioner means: Lockout: T3 probe off the pipe (FE repeated). It is also called Navien diagnostic code H8.

High severityAir ConditionerNavien NAA

Homeowner? What Navien code H8 means for you

Call a technician Your air conditioner is reporting: Lockout: T3 probe off the pipe (FE repeated). The air conditioner has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Keep about 2 feet around the outdoor unit clear of leaves, grass and debris.
  • If you see ice on the pipes or the indoor coil, turn the system off and run only the fan for a few hours, then call a technician.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Navien error code H8 mean?

FE happened 3 times within 120 minutes for the T3 coil probe and the unit has stopped.

Applies to: NAA17V36 (24K/36K), NAA17V60 (48K/60K)

Common causes of Navien code H8

  • T3 probe off the pipe or wrong spot
  • Damaged sensor
  • Outdoor PCB fault
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Navien models that use code H8

NAA17V36NAA17V60

Other Navien AC codes

CodeMeaning
H2Lockout: high pressure switch (P1 repeated)
H3High pressure abnormal (sensor over 3.6 MPa) - heating mode
H4Lockout: drive module overheating (P8 repeated)
H5Lockout: low pressure (P2 repeated)
H6Lockout: high discharge temperature (P4 repeated)
H7Lockout: low discharge superheat (PC repeated)
HCLockout: discharge probe off the pipe (FE repeated)
HERepeated condensate-risk faults (F8)
HICharging mode: outdoor air too hot
L0DC bus voltage too low
L1DC bus voltage too high
LACompressor speed held back by voltage

All Navien Air Conditioner error codes →

Navien code H8: homeowner questions

What does Navien code H8 mean?

Lockout: T3 probe off the pipe (FE repeated). FE happened 3 times within 120 minutes for the T3 coil probe and the unit has stopped.

Is it safe to keep using my air conditioner with code H8?

It depends on the cause. The air conditioner has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Navien code H8 myself?

You can try one reset (power off for 30 seconds, then on). If Navien code H8 comes back, the cause is still there and a licensed technician should check it.

Who can fix Navien code H8 near me?

Aurora Star Tech Inc. repairs Navien air conditioners in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check

Troubleshooting guides

Source: Navien NAA Series Air Conditioner Service Manual, 3.2.7, p.26. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977