Navien Error Code E157: Air volume control fault (Tankless)

Updated · by Aurora Star Tech Inc.

Navien error code E157 on a tankless water heater means: Air volume control fault. It is also called Navien diagnostic code E157.

High severityTankless Water HeaterNavien NHW700

Homeowner? What Navien code E157 means for you

Call a technician Your tankless water heater is reporting: Air volume control fault. The tankless water heater has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check that gas reaches the house: other gas appliances work, or the propane tank is not empty.
  • Make sure the heater is plugged in and its breaker is on. In winter, keep the power on: it protects the unit from freezing.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the hot and cold water valves under the heater are fully open.
  • If you have a remote controller, turn it off and on once. If the code comes back, call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Navien error code E157 mean?

During pre-purge the control could not bring the air flow (read by the APS) up to the ignition level within 25 seconds, more than 10 times in a row. Needs a manual reset.

Applies to: NHW700-120SE/160SE/180SE/199SE, NHW700-160SU/180SU/199SU, NHW700-160AI/180AI/199AI, NHW700-160AE/180AE/199AE

Common causes of Navien code E157

  • APS hose kinked or bent
  • APS hose on the fan (minus) side damaged
  • APS hoses on the wrong ports

A technician checks these and 3 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Navien models that use code E157

NHW700-120SENHW700-160AENHW700-160AINHW700-160SENHW700-160SUNHW700-180AENHW700-180AINHW700-180SENHW700-180SUNHW700-199AENHW700-199AINHW700-199SENHW700-199SU

Other Navien Tankless codes

CodeMeaning
E056Modulating gas valve fault
E060Dual venturi abnormal
E21No hot water
E109Fan motor abnormal
E110Abnormal air pressure
E127Air pressure sensor (APS) fault
E170Antifreeze heater open or short
E407Hot water outlet thermistor open or shorted
E421Cold water inlet 1 thermistor open or shorted
E432Cold water inlet 2 thermistor open or shorted
E434Water adjustment valve abnormal
E438Circulation pump abnormal (with air handler)

All Navien Tankless Water Heater error codes →

Navien code E157: homeowner questions

What does Navien code E157 mean?

Air volume control fault. During pre-purge the control could not bring the air flow (read by the APS) up to the ignition level within 25 seconds, more than 10 times in a row. Needs a manual reset.

Is it safe to keep using my tankless water heater with code E157?

It depends on the cause. The tankless water heater has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Navien code E157 myself?

You can try one reset (power off for 30 seconds, then on). If Navien code E157 comes back, the cause is still there and a licensed technician should check it.

Who can fix Navien code E157 near me?

Aurora Star Tech Inc. repairs Navien tankless water heaters in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Tankless Water Heater No Hot Water: What to Check

Troubleshooting guides

Source: Navien NHW700 Non-Condensing Water Heater Service Manual (V1.0, Apr 2023), 7.1 p.88, 7.2 p.90, 7.3.10 p.105, 5.5 p.75. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.