Replace refrigerant pressure sensor on a Navien air conditioner: The pressure sensor is brazed into the refrigerant circuit. The refrigerant must be recovered first and fire precautions apply during brazing.

Homeowner with a air conditioner problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NAA17V36 and NAA17V60

How to fix replace refrigerant pressure sensor: step by step

  1. Turn off the circuit breaker.
  2. Remove the 10 top cover screws and the 10 screws on the top and bottom side panels, then remove the top cover and panels.
  3. Recover all refrigerant from the refrigerant circuit before any heat work.
  4. Disconnect the wiring connectors from the PCB.
  5. Disconnect the pressure sensor connector.
  6. Wrap a wet cloth around the components near the sensor.
  7. Heat the brazing point of the sensor pipe with a torch and use pliers to pull the sensor pipe off the refrigerant pipe. The pipe can also be cut and the remaining stub heated off.
  8. To install: remove the plug or cap and make sure the pipe is clean.
  9. Install the sensor in the correct location.
  10. Wrap a wet cloth around the sensor and nearby parts, keep a nitrogen purge running, then braze the sensor pipe to the refrigerant pipe.
  11. Route the sensor harness to the PCB and connect the sensor connector.
  12. Secure the harness with new cable ties.
  13. Pull a vacuum on the system, then add refrigerant.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Air Conditioner codes

Source: Navien NAA air conditioner service manual, p. 49-50. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.