Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Navien Error Code FD: Pressure sensor not detected (Heat Pump)

Updated · by Aurora Star Tech Inc.

Navien error code FD on a heat pump means: Pressure sensor not detected. It is also called Navien diagnostic code FD.

High severityHeat PumpNavien NAZ

Homeowner? What Navien code FD means for you

Call a technician Your heat pump is reporting: Pressure sensor not detected. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Navien error code FD mean?

The PCB is not seeing the refrigerant pressure sensor.

Applies to: NAZ17V36 (24K/36K), NAZ17V60 (48K/60K)

Common causes of Navien code FD

  • Pressure sensor plug loose
  • Failed pressure sensor
  • Outdoor PCB fault
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Navien models that use code FD

NAZ17V36NAZ17V60

Other Navien Heat Pump codes

CodeMeaning
F7T7 sensor fault
F8T7 sensor: condensate risk on the cooling plate
F9Line voltage too low or too high
FAOutdoor board memory (EEPROM) fault
FBDrive chip memory (EEPROM) fault
FCDrive module temperature sensor fault
FET3 or T5 probe out of position
FFHigh pressure switch reads open all the time
H0Communication fault between chips on the outdoor PCB
H1Lockout: outdoor coil too hot (P5 repeated)
H2Lockout: high pressure switch (P1 repeated)
H3Lockout: high pressure in heating (PD repeated)

All Navien Heat Pump error codes →

Navien code FD: homeowner questions

What does Navien code FD mean?

Pressure sensor not detected. The PCB is not seeing the refrigerant pressure sensor.

Is it safe to keep using my heat pump with code FD?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Navien code FD myself?

You can try one reset (power off for 30 seconds, then on). If Navien code FD comes back, the cause is still there and a licensed technician should check it.

Who can fix Navien code FD near me?

Aurora Star Tech Inc. repairs Navien heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Navien NAZ Series Heat Pump Service Manual (V1.00), 4.2.6, p.32-33. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977