Navien Error Code P9: Outdoor fan motor fault (AC)

Updated · by Aurora Star Tech Inc.

Navien error code P9 on a air conditioner means: Outdoor fan motor fault. It is also called Navien diagnostic code P9.

High severityAir ConditionerNavien NAA

Homeowner? What Navien code P9 means for you

Call a technician Your air conditioner is reporting: Outdoor fan motor fault. The air conditioner has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Keep about 2 feet around the outdoor unit clear of leaves, grass and debris.
  • If you see ice on the pipes or the indoor coil, turn the system off and run only the fan for a few hours, then call a technician.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Navien error code P9 mean?

The fan drive circuit on the outdoor board saw a problem with the DC fan motor.

Applies to: NAA17V36 (24K/36K), NAA17V60 (48K/60K)

Common causes of Navien code P9

  • Supply voltage problem
  • Failed DC fan motor
  • PCB fan drive fault
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Navien models that use code P9

NAA17V36NAA17V60

Other Navien AC codes

CodeMeaning
P2Low pressure protection
P3Compressor drive overcurrent
P4Discharge temperature too high
P5Condenser coil (T3) temperature too high - cooling
P6Compressor drive (IPM) module protection
P8Drive module (IPM) overheating
PCLow discharge superheat (liquid floodback risk)
PC, H7Moisture exposure error (overheat, T5-T3 under 9°F / 5°C)
PDHigh pressure too high
PRHCrankcase heater warm-up, no start yet
R101Condenser heat exchange abnormal alarm
R301Supply solenoid valve stuck alarm

All Navien Air Conditioner error codes →

Navien code P9: homeowner questions

What does Navien code P9 mean?

Outdoor fan motor fault. The fan drive circuit on the outdoor board saw a problem with the DC fan motor.

Is it safe to keep using my air conditioner with code P9?

It depends on the cause. The air conditioner has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Navien code P9 myself?

You can try one reset (power off for 30 seconds, then on). If Navien code P9 comes back, the cause is still there and a licensed technician should check it.

Who can fix Navien code P9 near me?

Aurora Star Tech Inc. repairs Navien air conditioners in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check

Troubleshooting guides

Source: Navien NAA Series Air Conditioner Service Manual, 3.2.16, p.40-41. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.