Navien Error Code HC: Lockout: discharge probe off the pipe (FE repeated) (AC)

Updated · by Aurora Star Tech Inc.

Navien error code HC on a air conditioner means: Lockout: discharge probe off the pipe (FE repeated). It is also called Navien diagnostic code HC.

High severityAir ConditionerNavien NAA

Homeowner? What Navien code HC means for you

Call a technician Your air conditioner is reporting: Lockout: discharge probe off the pipe (FE repeated). The air conditioner has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Keep about 2 feet around the outdoor unit clear of leaves, grass and debris.
  • If you see ice on the pipes or the indoor coil, turn the system off and run only the fan for a few hours, then call a technician.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Navien error code HC mean?

FE happened 3 times within 180 minutes for the T5 discharge probe and the unit has stopped.

Applies to: NAA17V36 (24K/36K), NAA17V60 (48K/60K)

Common causes of Navien code HC

  • T5 probe off the discharge line or wrong spot
  • Damaged sensor
  • Outdoor PCB fault
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Navien models that use code HC

NAA17V36NAA17V60

Other Navien AC codes

CodeMeaning
H3High pressure abnormal (sensor over 3.6 MPa) - heating mode
H4Lockout: drive module overheating (P8 repeated)
H5Lockout: low pressure (P2 repeated)
H6Lockout: high discharge temperature (P4 repeated)
H7Lockout: low discharge superheat (PC repeated)
H8Lockout: T3 probe off the pipe (FE repeated)
HERepeated condensate-risk faults (F8)
HICharging mode: outdoor air too hot
L0DC bus voltage too low
L1DC bus voltage too high
LACompressor speed held back by voltage
LBCompressor speed held back by high pressure

All Navien Air Conditioner error codes →

Navien code HC: homeowner questions

What does Navien code HC mean?

Lockout: discharge probe off the pipe (FE repeated). FE happened 3 times within 180 minutes for the T5 discharge probe and the unit has stopped.

Is it safe to keep using my air conditioner with code HC?

It depends on the cause. The air conditioner has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Navien code HC myself?

You can try one reset (power off for 30 seconds, then on). If Navien code HC comes back, the cause is still there and a licensed technician should check it.

Who can fix Navien code HC near me?

Aurora Star Tech Inc. repairs Navien air conditioners in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check

Troubleshooting guides

Source: Navien NAA Series Air Conditioner Service Manual, 3.2.7, p.26. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977