Navien Error Code PC, H7: Moisture exposure error (overheat, T5-T3 under 9°F / 5°C) (AC)

Updated · by Aurora Star Tech Inc.

Navien error code PC, H7 on a air conditioner means: Moisture exposure error (overheat, T5-T3 under 9°F / 5°C). It is also called Navien diagnostic code PC, H7.

High severityAir ConditionerNAA Series

Homeowner? What Navien code PC, H7 means for you

Call a technician Your air conditioner is reporting: Moisture exposure error (overheat, T5-T3 under 9°F / 5°C). The air conditioner has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Keep about 2 feet around the outdoor unit clear of leaves, grass and debris.
  • If you see ice on the pipes or the indoor coil, turn the system off and run only the fan for a few hours, then call a technician.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Navien error code PC, H7 mean?

The system has detected moisture exposure. The check compares the discharge temperature sensor T5 with the coil sensor T3, and the unit trips when T5-T3 is 9°F (5°C) or less.

Applies to: NAA17V36-24K/36K, NAA17V60-48K/60K

Common causes of Navien code PC, H7

  • Air or nitrogen mixed into the refrigerant system
  • Abnormal resistance on the T5 or T3 sensor
  • Parameters 6 and 8 do not match the measured temperatures

A technician checks these and 1 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Navien AC codes

CodeMeaning
P4Discharge temperature too high
P5Condenser coil (T3) temperature too high - cooling
P6Compressor drive (IPM) module protection
P8Drive module (IPM) overheating
P9Outdoor fan motor fault
PCLow discharge superheat (liquid floodback risk)
PDHigh pressure too high
PRHCrankcase heater warm-up, no start yet
R101Condenser heat exchange abnormal alarm
R301Supply solenoid valve stuck alarm
R302Drain solenoid valve stuck alarm
R303Water supply abnormality alarm

All Navien Air Conditioner error codes →

Navien code PC, H7: homeowner questions

What does Navien code PC, H7 mean?

Moisture exposure error (overheat, T5-T3 under 9°F / 5°C). The system has detected moisture exposure. The check compares the discharge temperature sensor T5 with the coil sensor T3, and the unit trips when T5-T3 is 9°F (5°C) or less.

Is it safe to keep using my air conditioner with code PC, H7?

It depends on the cause. The air conditioner has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Navien code PC, H7 myself?

You can try one reset (power off for 30 seconds, then on). If Navien code PC, H7 comes back, the cause is still there and a licensed technician should check it.

Who can fix Navien code PC, H7 near me?

Aurora Star Tech Inc. repairs Navien air conditioners in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check

Troubleshooting guides

Source: Navien NAA air conditioner service manual, p. 42-43. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.