Navien Air Conditioner: Replace refrigerant high pressure switch
Replace refrigerant high pressure switch on a Navien air conditioner: The high pressure switch is brazed into the refrigerant line. Recover refrigerant before heating the joint.
Applies to: NAA17V36 and NAA17V60
How to fix replace refrigerant high pressure switch: step by step
- Turn off the circuit breaker.
- Remove the 10 top cover screws and the 10 screws on the top and bottom side panels, then remove the top cover and panels.
- Recover all refrigerant from the refrigerant circuit before any heat work.
- Disconnect the wiring connectors from the PCB.
- Wrap a wet cloth around the components near the switch.
- Heat the brazing point of the switch pipe with a torch and use pliers to remove the switch pipe from the refrigerant pipe.
- To install: remove the plug or cap and make sure the pipe is clean.
- Install the switch in the correct location.
- Wrap a wet cloth around the switch and nearby parts, then braze the switch pipe to the refrigerant pipe.
- Route the harness to the PCB and connect it.
- Add refrigerant to the refrigerant circuit.
If the unit shows an error code, look it up: Navien Air Conditioner codes
Source: Navien NAA air conditioner service manual, p. 50-51. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.