Navien Heat Pump error codes list

CodeMeaningSeverity
ATLOutdoor temperature outside operating rangeMedium
d0Oil return cycleLow
dCForced coolingLow
dfDefrostLow
F4T4 outdoor ambient sensor faultMedium
F5T5 compressor discharge sensor faultMedium
F6T3 condenser coil sensor faultMedium
F7T7 sensor faultMedium
F8T7 sensor: condensate risk on the cooling plateMedium
F9Line voltage too low or too highHigh
FAOutdoor board memory (EEPROM) faultHigh
FBDrive chip memory (EEPROM) faultHigh
FCDrive module temperature sensor faultHigh
FDPressure sensor not detectedHigh
FET3 or T5 probe out of positionMedium
FFHigh pressure switch reads open all the timeHigh
H0Communication fault between chips on the outdoor PCBHigh
H1Lockout: outdoor coil too hot (P5 repeated)High
H2Lockout: high pressure switch (P1 repeated)High
H3Lockout: high pressure in heating (PD repeated)High
H4Lockout: drive module overheating (P8 repeated)High
H5Lockout: low pressure (P2 repeated)High
H6Lockout: high discharge temperature (P4 repeated)High
H7Lockout: low discharge superheat (PC repeated)High
H8Lockout: T3 probe off the pipe (FE repeated)High
HCLockout: discharge probe off the pipe (FE repeated)High
HERepeated condensate-risk faults (F8)Medium
IoT LED bootIoT module boot modeLow
IoT LED pairingIoT module pairing / operationLow
IoT Wi-Fi LED colorIoT Wi-Fi signal colorLow
L0DC bus voltage too lowHigh
L1DC bus voltage too highHigh
LACompressor speed held back by voltageLow
LBCompressor speed held back by high pressureLow
LCCompressor speed held back by condenser temperatureLow
LDCompressor speed held back by discharge temperatureLow
LECompressor speed held back by drive module temperatureLow
LFCompressor speed held back by currentLow
P1High pressure switch openedHigh
P2Low pressure protectionHigh
P3Compressor drive overcurrentHigh
P4Discharge temperature too highHigh
P5Outdoor coil too hot in coolingHigh
P6Compressor drive (IPM) module protectionCritical
P7Indoor coil freeze protection (T2)High
P8Drive module (IPM) overheatingHigh
P9Outdoor fan motor faultHigh
PCLow discharge superheat (liquid floodback risk)High
PDHigh pressure too high in heatingHigh
PRHCrankcase heater warm-up, no start yetLow

Find codes by Navien model

NAZ17V36NAZ17V60

Heat Pump troubleshooting guides

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.