Navien Error Code E594: EEPROM fault (Combi Boiler)
Navien error code E594 on a combi boiler means: EEPROM fault. It is also called Navien diagnostic code E594.
Homeowner? What Navien code E594 means for you
Check, then call Your combi boiler is reporting: EEPROM fault. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
- Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
- Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
- Check that the boiler gas valve is open (handle in line with the pipe).
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
- If only hot water is missing, check that the hot water tap is open far enough to start the heater.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Navien error code E594 mean?
The control memory (EEPROM) has a fault. NFC-H manual lists the reset type as: Alarm.
Applies to: Navien fire-tube combi boilers, NFC-H series (NFC-250/200H, NFC-250/175H) and NCB-H combi boilers (NCB-250/150H, NCB-240/130H, NCB-240/110H, NCB-190/080H, NCB-190/060H)
Common causes of Navien code E594
- Control board memory fault
Navien models that use code E594
NCB-190/060HNCB-190/080HNCB-240/110HNCB-240/130HNCB-250/150HNFC-250/175HNFC-250/200H
Other Navien Combi Boiler codes
All Navien Combi Boiler error codes →
Navien code E594: homeowner questions
What does Navien code E594 mean?
EEPROM fault. The control memory (EEPROM) has a fault. NFC-H manual lists the reset type as: Alarm.
Is it safe to keep using my combi boiler with code E594?
It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.
Can I reset Navien code E594 myself?
You can try one reset (power off for 30 seconds, then on). If Navien code E594 comes back, the cause is still there and a licensed technician should check it.
Who can fix Navien code E594 near me?
Aurora Star Tech Inc. repairs Navien combi boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: Tankless Water Heater No Hot Water: What to Check · Boiler Not Heating: What to Check
Troubleshooting guides
- Annual maintenance check Navien · Combi Boiler
- CH series breaker trips or remote has no power Navien · Combi Boiler
- CH series cleaning the intake air filter Navien · Combi Boiler
- CH series E001 boiling in heat exchanger - full check Navien · Combi Boiler
- CH series E002 low water pressure / auto fill - full check Navien · Combi Boiler
- CH series E003 ignition failure - full check Navien · Combi Boiler
- CH series E004 false flame - full check Navien · Combi Boiler
- CH series E005 / E006 heating supply thermistor - full check Navien · Combi Boiler
Source: Navien NCB-H Installation & Operation Manual, 11.7 Understanding Error Codes, p.129-130; Navien NFC-H Installation Manual, 11.7 Understanding Error Codes, p.127-128. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.