Trane Furnace error codes list

CodeMeaningSeverity
---Faults cleared confirmationLow
2 FlashesSystem lockoutHigh
3 FlashesDraft pressure errorHigh
4 FlashesOpen high limit deviceHigh
5 FlashesFlame sensed with no flame expectedHigh
6 Flashes115 V AC power reversed or poor groundingMedium
7 FlashesGas valve circuit errorHigh
8 FlashesLow flame sense signalHigh
9 FlashesIgnitor circuit or neutral-to-common voltageHigh
ARFCalculated airflow readout (cfm x 10)Low
Both LEDs flashing togetherBluetooth pairing in progressLow
CL1Cooling, stage 1Low
CL2Cooling, stage 2Low
CoFContinuous fan demandLow
Continuous OFFCheck powerMedium
Continuous ONReplace integrated furnace controlHigh
CP1Cooling / heat pump, stage 1 (single-stage models)Low
CP2Cooling / heat pump, stage 2Low
CrControl code release numberLow
dFtOutdoor defrost demandLow
E01Furnace control internal failureHigh
E04Open limit (main limit, rollout or reverse airflow)High
E05Flame sensed when no flame should be presentCritical
E08Low flame signal (still running)Low
E2.1Ignition retries exceeded - flame never proven (1 hour lockout)High
E2.2Flame recycles exceeded - flame lost after lighting (1 hour lockout)High
E2.31st stage gas valve not powered when it should be (10 times)High
E3.11st stage pressure switch (PS1) closed when it should be openMedium
E3.21st stage pressure switch (PS1) open when it should be closedMedium
E3.32nd stage pressure switch (PS2) closed when it should be openMedium
E3.42nd stage pressure switch (PS2) open when it should be closedMedium
E4.0Main high limit openHigh
E4.1Reverse airflow limit openHigh
E4.2Flame rollout switch openCritical
E6.1120 V polarity reversedMedium
E6.2Ground not detectedMedium
E6.3Igniter open or igniter relay faultHigh
E7.11st stage gas valve (MVL) powered with no callCritical
E7.2Redundant relay (HLO output) on with no callCritical
E11Gas valve relay / valve circuit faultHigh
E12Control fuse openMedium
E13Blower motor size / OEM ID mismatchMedium
E14Configuration file errorMedium
E17Blower motor communication errorHigh
E23Menu data not received by combustion micro (CCM)Medium
E24Internal communication error between ACM and CCMMedium
E25Orientation sensor out of rangeLow
E26Return static pressure sensor out of range or not connectedLow
E27Return air thermistor out of range or not connectedLow
E28Supply air thermistor out of range or not connectedLow
errActive alarm menuLow
FDFactory default reset doneLow
Flashing FastNormal - call for heatLow
Flashing SlowNormal - no call for heatLow
HLdHold during run testLow
HP1Heat pump, stage 1 demandLow
HP2Heat pump, stage 2 demandLow
HtGas heating (single-stage models)Low
Ht1Gas heat, stage 1 demandLow
Ht2Gas heat, stage 2 demandLow
IdLIdle - no demandLow
L6FLast 6 faults menuLow
LED continuous OFFNo power to controlHigh
LED continuous ONIFC board fault - replace controlHigh
LED flashing fastNormal - call for heatLow
LEDs both solidPower-upLow
MNRModel number recoveryLow
rAtReturn air temperature readoutLow
rSPReturn static pressure readoutLow
runRun test modeLow
SAtSupply air temperature readoutLow
Status LED 1 flashActive demand (LED)Low
Status LED off, comm LED on/countingIdle (LEDs)Low
tP1 to tP9Blower tap in useLow
uErVerification test modeLow

Find codes by Trane model

UH1/DH1

DH1B040A9241DH1B065A9421DH1C085A9481DH1D110A9601UC1B060CUH1C080A9601UH1C100A9481UH1D100A9601UH1D120A9601

Trane S8B1

S8B1A026M2PSABS8B1A040M3PSABS8B1B040M2PSABS8B1B060M3PSABS8B1B060M4PSABS8B1B080M4PSABS8B1C080M5PSABS8B1C100M5PSABS8B1D120M5PSAB

Trane S8V2

S8V2A040M3PCBS8V2A040M3PDS8V2B060M4PCBS8V2B060M4PDS8V2B080M4PCBS8V2B080M4PDS8V2C080M5PCBS8V2C080M5PDS8V2C100M5PCBS8V2C100M5PDS8V2D120M5PCBS8V2D120M5PD

Trane S8X1

S8X1A026M2PSABS8X1A040M3PSABS8X1B040M2PSABS8X1B060M3PSABS8X1B060M4PSABS8X1B080M4PSABS8X1C080M5PSABS8X1C100M5PSABS8X1D120M5PSAB

Trane S8X2

S8X2A040M3PSABS8X2B060M3PSABS8X2B060M4PSABS8X2B080M4PSABS8X2C080M5PSABS8X2C100M5PSABS8X2D120M5PSAB

Trane S9V2

S9V2B040U3VSACS9V2B060U3VSACS9V2B080D4VSACS9V2B080U4VSACS9V2C100D4VSACS9V2C100U4VSACS9V2D120U5VSAC

UH1

UH1B040A9241AUH1B060A9361AUH1B080A9421BUH1C080A9601AUH1C100A9481AUH1D100A9601AUH1D120A9601A

Furnace troubleshooting guides

Trane Furnace specs and setup data

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.