Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Trane Furnace: Reading and clearing fault history – Trane S-Series IFC

Updated · by Aurora Star Tech Inc.

Reading and clearing fault history - Trane S-Series IFC on a Trane furnace: How to pull up stored faults, wipe them and reset the furnace control to factory values with the Menu and Option buttons.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Trane S8V2 (80%, 2-stage, variable speed, Link) and S8B1 / S8X1 / S8X2 (80%, 1- and 2-stage)

Common causes of reading and clearing fault history - trane s-series ifc

  • Intermittent faults that are no longer active
  • Settings changed by others

How to fix reading and clearing fault history - trane s-series ifc: step by step

  1. WARNING: Touch only the Menu and Option buttons on a powered board.
  2. Active faults: scroll with Menu to 'err'. Stored faults: scroll to 'L6F' and press Option to step through the last 6.
  3. To erase history: inside L6F hold Option 5 seconds or more; three dashes flashing 3 times confirm it is cleared.
  4. Factory defaults: with the display at idle, press Menu and Option together for 15 seconds; 'FD' flashing 3 times confirms.
  5. While running, the display alternates mode and airflow every 2 seconds; an E-code flashes in between if a fault is active.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Trane Furnace codes

Models

Trane S8B1

S8B1A026M2PSABS8B1A040M3PSABS8B1B040M2PSABS8B1B060M3PSABS8B1B060M4PSABS8B1B080M4PSABS8B1C080M5PSABS8B1C100M5PSABS8B1D120M5PSAB

Trane S8V2

S8V2A040M3PCBS8V2A040M3PDS8V2B060M4PCBS8V2B060M4PDS8V2B080M4PCBS8V2B080M4PDS8V2C080M5PCBS8V2C080M5PDS8V2C100M5PCBS8V2C100M5PDS8V2D120M5PCBS8V2D120M5PD

Trane S8X1

S8X1A026M2PSABS8X1A040M3PSABS8X1B040M2PSABS8X1B060M3PSABS8X1B060M4PSABS8X1B080M4PSABS8X1C080M5PSABS8X1C100M5PSABS8X1D120M5PSAB

Trane S8X2

S8X2A040M3PSABS8X2B060M3PSABS8X2B060M4PSABS8X2B080M4PSABS8X2C080M5PSABS8X2C100M5PSABS8X2D120M5PSAB

Source: Trane FNR-SVX003A-EN and 18-CE14D1-1A-EN - section Fault Code Recovery. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.