Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Trane Furnace: Burner box cover reinstallation

Updated · by Aurora Star Tech Inc.

Burner box cover reinstallation on a Trane furnace: Use this method when the cover is removed to service the flame sensor, hot surface igniter or orifices.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Burner box service

How to fix burner box cover reinstallation: step by step

  1. Insert the top flange of the front cover under the lip inside the box.
  2. Rotate the front cover inward, making sure all side flanges are outside the box.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Trane Furnace codes

More other tips for furnace

Source: Trane 18-CD29D1-11 installer's guide, p. 39. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977