Trane Furnace: Condensate drain freeze protection
Condensate drain freeze protection on a Trane furnace: A frozen condensate drain shuts the furnace down.
Applies to: Condensate drain installations
How to fix condensate drain freeze protection: step by step
- Use 1/2 in. or larger PVC or CPVC drain piping.
- If the drain runs outside conditioned space, apply UL listed heat tape rated 5 or 6 W/ft at 120 V.
- Use self-regulating or thermostatically controlled heat tape, installed per manufacturer instructions.
- Use a corrosion resistant condensate pump if a pump is required.
- Where the furnace is above a finished ceiling, route the primary drain vent overflow into an auxiliary drain pan.
If the unit shows an error code, look it up: Trane Furnace codes
Source: Trane 18-CD29D1-11 installer's guide, p. 32. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.