Trane Furnace: Condensate drain freeze protection

Updated · by Aurora Star Tech Inc.

Condensate drain freeze protection on a Trane furnace: A frozen condensate drain shuts the furnace down.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Condensate drain installations

How to fix condensate drain freeze protection: step by step

  1. Use 1/2 in. or larger PVC or CPVC drain piping.
  2. If the drain runs outside conditioned space, apply UL listed heat tape rated 5 or 6 W/ft at 120 V.
  3. Use self-regulating or thermostatically controlled heat tape, installed per manufacturer instructions.
  4. Use a corrosion resistant condensate pump if a pump is required.
  5. Where the furnace is above a finished ceiling, route the primary drain vent overflow into an auxiliary drain pan.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Trane Furnace codes

More other tips for furnace

Source: Trane 18-CD29D1-11 installer's guide, p. 32. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.